8 LFC300-DOSY-GPM

Item Number: 0124615
Skip to product information
1 of 1
Regular price $21,147.00
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 8 inch
  • Weight: 490.0 lb
  • Lead Free: Yes (wetted surfaces < 0.25% lead)
  • Housing Material: 304 Stainless Steel
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 110°F
  • Shutoff Valves: Domestic OSY
  • Bypass Meter: Gallons-per-minute
  • Approvals: AWWA C510-97, ASSE 1048, CSA B64.5, UL, FM, NSF/ANSI 372

Description

The Colt LFC300N 8 inch lead-free double check detector backflow preventer assembly prevents backflow of non-toxic pollutants into potable water systems. Designed for fire line sprinkler systems and other non-health hazard applications, it monitors unauthorized water use with a gallons-per-minute metered bypass. This compact unit features a 304 stainless steel housing, domestic OSY shutoff valves, and patented Tri-Link check valves for low pressure loss and easy serviceability. Approved by AWWA C510-97, ASSE 1048, CSA B64.5, UL, FM, and NSF/ANSI 372, it offers reliable protection with a maximum working pressure of 175 psi and a temperature range of 33°F to 110°F.

Help Me Connect

Connections

  • The main assembly features groove end connections for integral pipeline adjustment.
  • The bypass assembly is equipped with ASME/ANSI flanged end connections.
  • The unit includes domestic outside stem and yoke (OS&Y) resilient seated gate valves for reliable shutoff.

Installation Configurations

  • This backflow preventer can be installed in horizontal, vertical up, or "N" pattern horizontal configurations.
View full details

Collapsible content

Additional Details

The Colt LFC300N 8 inch lead-free double check detector backflow preventer assembly prevents backflow of objectionable pollutants, but not toxic substances, from entering the potable water supply system. It is ideal for use on fire line sprinkler systems to monitor unauthorized water use, and in other non-health hazard applications.

This assembly provides protection at cross-connections identified as non-health hazards and ensures compliance with national plumbing codes and water authority requirements.

Key Features

  • Compact modular design with a single access cover for easy maintenance
  • Approximately 70% lighter than traditional designs
  • Housing and sleeve constructed from 304 (Schedule 40) stainless steel
  • Groove fittings allow integral pipeline adjustment
  • Patented Tri-Link check valves provide lowest pressure loss
  • Unmatched ease of serviceability – no special tools required
  • Designed for horizontal, vertical, or "N" pattern installations
  • Includes a gallons-per-minute metered bypass to detect underground leaks and unauthorized water use
  • Equipped with four test cocks for easy monitoring and testing
  • Lead-free construction ensures the wetted surfaces contain less than 0.25% lead by weight

Components

  • Features domestic outside stem and yoke (OS&Y) resilient seated gate valves
  • Consists of two independent Tri-Link Check modules with reversible elastomer discs
  • Bypass assembly includes a meter (gallon or cubic measurement) and a double check valve assembly
  • Integrated supervisory switch is an option on each gate valve of the OS&Y model

Specifications

  • Product Type: Double Check Detector Backflow Preventer Assembly
  • Nominal Size: 8 inch
  • Model: LFC300N
  • Configurations: Horizontal, Vertical Up, "N" Pattern Horizontal
  • Shutoff Valves: Domestic Outside Stem and Yoke (OSY)
  • Bypass Meter: Gallons-per-minute
  • Lead Free: Yes (wetted surfaces < 0.25% lead by weight)

Materials

  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, and Buna 'N'
  • Tri-Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks: Lead Free Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel

Performance

  • Maximum Working Pressure: 175 psi (12.06 bar)
  • Temperature Range: 33°F - 110°F (5°C - 43°C)

Dimensions (8 inch LFC300N)

  • Length (A): 49 3/4 inch (1264 mm)
  • OSY Height (C): 37 3/4 inch (959 mm)
  • Flange Diameter (D): 6 11/16 inch (170 mm)
  • Overall Length (G): 54 1/8 inch (1375 mm)
  • Bypass Height (H): 40 1/8 inch (1019 mm)
  • OSY Valve Width (J): 15 11/16 inch (399 mm)
  • Test Cock Length (P): 21 3/16 inch (538 mm)
  • Weight: 574 lb (260 kg)

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C510-97
  • ASSE 1048
  • CSA B64.5
  • UL Classified
  • FM Approved
  • NSF Certified to NSF/ANSI 372

FAQs

What is the primary purpose of the Colt LFC300N backflow preventer?

The Colt LFC300N is designed to prevent the backflow of non-toxic pollutants into the potable water supply. It is specifically used on fire line sprinkler systems to monitor unauthorized water use and in other non-health hazard applications.

What materials are used in the construction of this backflow preventer?

The housing and sleeve are made from 304 (Schedule 40) stainless steel. It features reversible silicone or EPDM check discs, Noryl® and stainless steel Tri-Link checks, and lead-free bronze body test cocks.

What does "lead-free" mean for this product?

"Lead-free" signifies that the wetted surfaces of this backflow preventer, which come into contact with consumable water, contain less than 0.25% lead by weight, meeting industry standards for safe water systems.

What are the available installation configurations for the LFC300N?

This backflow preventer assembly can be installed in horizontal, vertical up, or "N" pattern horizontal configurations, offering flexibility for various piping layouts.

Does this assembly include a bypass meter?

Yes, it includes a gallons-per-minute metered bypass assembly. This feature is crucial for detecting underground leaks and unauthorized water usage in the system.