8 M300-BFG-GPM

Item Number: 0191428
Skip to product information
1 of 1
Regular price $24,837.75
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 8 inch
  • Weight: 510.0 lb
  • Body Material: Stainless Steel
  • Valve Type: Grooved Gear Operated Butterfly Valves
  • Maximum Working Pressure: 175 PSI
  • Features: Gallon per Minute (GPM) Meter
  • Installation: Horizontal or Vertical
  • Check Valve Type: Tri-link
  • Includes: Four test cocks

Description

The 8 inch Maxim™ Double Check Detector Backflow Preventer Assembly from Ames Fire & Waterworks (SKU 0191428) is engineered to prevent the reverse flow of non-potable water and fire protection substances into the potable water supply. Constructed with a durable stainless steel body and tri-link check valves, it offers reliable protection against backsiphonage and backpressure. Key features include grooved gear operated butterfly valves, a gallon per minute (GPM) meter for leak detection, and four test cocks for maintenance. Approved for horizontal or vertical installation, this assembly has a maximum working pressure of 175 PSI, making it suitable for fire sprinkler systems and non-health hazard cross-connections.

Help Me Connect

Connections & Installation

This 8 inch Maxim™ double check detector backflow preventer assembly features grooved connections for installation. It is equipped with grooved gear operated butterfly valves. The assembly is designed for installation in either a horizontal or vertical orientation, aligning with the direction of the flow arrow on the unit. For optimal performance and compliance, ensure adequate clearance is maintained around the valve for inspection, testing, and servicing, as outlined in the installation considerations. The standard tap size for this 8-inch model is 3/4 inch.

View full details

Collapsible content

Additional Details

This 8 inch Maxim™ double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply. It protects against backsiphonage and backpressure in accordance with national plumbing codes and water authority requirements.

It is ideal for protecting cross-connections identified as non-health hazards, such as on fire sprinkler systems and to prevent contaminants at the service line entrance. This compact assembly is approved for horizontal or vertical installation, following the direction of the flow arrow.

Construction & Features

  • Features a stainless steel body with a single access sleeve for easy maintenance.
  • Equipped with tri-link check valves for the lowest pressure loss.
  • Includes grooved gear operated butterfly valves with a tamper switch.
  • Furnished with a gallon per minute (GPM) meter to detect underground leaks and unauthorized water use.
  • Compact modular design allows for smaller vaults and enclosures.
  • Stainless steel construction provides long-term corrosion protection and maximum strength.
  • Features replaceable check disc rubber.
  • Includes four test cocks for easy testing.

Installation Notice: The information provided is not intended to replace full product installation and safety information. A trained product installer should thoroughly read all instructions before beginning installation.

Specifications

General

  • Product Type: Double Check Detector Backflow Preventer Assembly
  • Brand: Ames Fire & Waterworks (Maxim Series)
  • Size: 8 inch (200 mm)
  • Body Material: Stainless Steel
  • Valve Type: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Check Valve Type: Tri-link
  • Meter: Gallon per Minute (GPM) Meter
  • Test Cocks: Four included
  • Installation: Horizontal or Vertical
  • Maximum Working Pressure: 175 PSI (12.06 bar)

Dimensions (Approximate)

  • Nominal Size: 8 inch (200 mm)
  • Dimension A (Length): 11 1/2 inch (292 mm)
  • Dimension B: 5 3/4 inch (146 mm)
  • Dimension D (Overall Height): 22 1/2 inch (572 mm)
  • Dimension E: 5 3/4 inch (146 mm)
  • Dimension F: 8 1/4 inch (210 mm)
  • Standard Tap Size: 3/4 inch

FAQs

What is the primary purpose of this 8 inch Maxim backflow preventer?

Its primary purpose is to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply, protecting against both backsiphonage and backpressure.

What type of valves does this backflow preventer assembly use?

This assembly utilizes grooved gear operated butterfly valves, which are equipped with a tamper switch for added security and monitoring.

Can this backflow preventer be installed in any orientation?

Yes, this assembly is approved for installation in both horizontal and vertical orientations, provided it is installed in accordance with the direction of the flow arrow marked on the unit.

What is the significance of the gallon per minute (GPM) meter included with this assembly?

The integrated GPM meter allows for the detection of underground leaks and unauthorized water usage, providing an important monitoring capability for the system.

What is the maximum operating pressure for this 8 inch backflow preventer?

The maximum working pressure for this 8 inch Maxim double check detector backflow preventer assembly is 175 PSI (12.06 bar).