Watts 3/8" LF008PC-QT

Item Number: 0792023
Skip to product information
1 of 1
Regular price $1,293.75
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Lead Free* Cast Copper Silicon Alloy Body
  • Weight: 7.0 lb
  • Internal Polymer Coating
  • Quarter-Turn Shutoffs with Tee Handles
  • Spill-Resistant Design for Indoor Use
  • Modular Cartridge for Ease of Service
  • Maximum Working Pressure: 150 PSI
  • Temperature Range: 33°F - 180°F
  • Approved by IAPMO, ASSE 1056, CSA B64.4, NSF

Description

The Watts 3/8" LF008PC-QT is a Lead Free* anti-siphon, spill-resistant vacuum breaker backflow preventer designed for indoor point-of-use applications. It prevents the reverse flow of polluted water into potable water supplies due to backsiphonage. This unit features a durable Lead Free* cast copper silicon alloy body with an internal polymer coating, thermoplastic check and float assembly, stainless steel springs, and quarter-turn Tee handle shutoffs. It operates at a maximum working pressure of 150 PSI and a temperature range of 33°F to 180°F. Ideal for general plumbing on machines or equipment, it ensures water safety. Approved by IAPMO, ASSE 1056, CSA B64.4, and NSF. (*The wetted surface contains less than 0.25% lead by weight.)

Help Me Connect

The Watts 3/8" LF008PC-QT is designed for point-of-use installation in indoor applications to protect potable water supplies from pollution. It connects via Female NPT threads on both the inlet and outlet. For factory or field-applied general plumbing applications, ensure the critical level of the backflow preventer is installed a minimum of 6 inches (150mm) above the flood rim. A strainer is recommended upstream to prevent fouling of the check assembly.

Warranty Information

Limited Warranty:
Watts (the "Company") warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.
View full details

Collapsible content

Additional Details

The Watts 3/8" LF008PC-QT anti-siphon, spill-resistant vacuum breaker backflow preventer prevents the reverse flow of polluted water from entering into a potable water supply due to backsiphonage in indoor point-of-use applications. It is ideal for use on machines or equipment in general plumbing applications.

This backflow preventer features a Lead Free* cast copper silicon alloy body, an internal polymer coating, a thermoplastic check and float assembly valve, stainless steel springs, and Tee handles for quarter-turn shutoffs. A molded diaphragm separates the air inlet from the potable water supply to prevent spillage.

Features

  • Lead Free* construction complies with installation requirements
  • Standardly supplied with an internal polymer coating
  • Includes Tee handles for quarter-turn shutoffs
  • Spill-resistant design for indoor use
  • Modular cartridge for ease of service
  • Vent uses an O-ring for reliable operation
  • Bronze body (Lead Free* cast copper silicon alloy) for durability
  • Compact space saving design

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

Specifications

General

  • Brand: Watts
  • Model: LF008PCQT
  • SKU: 0792023
  • Size: 3/8 inch
  • Application: Indoor point-of-use, Health hazard, Anti-siphon, Spill-resistant

Materials

  • Body Material: Lead Free* Cast Copper Silicon Alloy
  • Springs: Stainless steel
  • O-Rings: EPDM
  • Vent Disc: PPO
  • Disc Holder: PPO
  • Check Disc: Silicone rubber
  • Internal Coating: Polymer

Performance

  • Maximum Working Pressure: 150 PSI (10.3 bar)
  • Minimum Working Pressure: 8 PSI (55.2 kPa)
  • Temperature Range: 33°F - 180°F (0.5°C - 83°C)

Connections

  • Inlet/Outlet: Female NPT
  • Shutoffs: Quarter-Turn Ball Valve with Tee Handles

Dimensions & Weight (Approximate)

  • Height (A): 5 1/2 inches (140 mm)
  • Width (B): 3 1/2 inches (100 mm)
  • Depth (C): 3 inches (76 mm)
  • Distance (D): 1 1/4 inches (32 mm)
  • Distance (E): 4 3/4 inches (121 mm)
  • Weight: 1.6 lbs (0.73 kg)

Certificates & Approvals

  • IAPMO
  • ASSE 1056
  • CSA B64.4
  • NSF

FAQs

What is the primary purpose of the Watts 3/8" LF008PC-QT backflow preventer?

Its primary purpose is to prevent the reverse flow of polluted water from entering into a potable water supply due to backsiphonage, specifically for indoor point-of-use applications.

Is this backflow preventer suitable for outdoor use?

No, the Watts LF008PC-QT is specifically designed and engineered for indoor point-of-use applications.

What are the maximum pressure and temperature ratings for this device?

This backflow preventer has a maximum working pressure of 150 PSI (10.3 bar) and can operate within a temperature range of 33°F to 180°F (0.5°C to 83°C).

What materials are used in the construction of the Watts LF008PC-QT?

It features a Lead Free* cast copper silicon alloy body, stainless steel springs, EPDM O-rings, PPO vent and disc holders, and a silicone rubber check disc. It also has an internal polymer coating.

What type of connections does the Watts 3/8" LF008PC-QT utilize?

This unit uses Female NPT connections for both the inlet and outlet, and includes quarter-turn ball valve shutoffs with Tee handles.