Watts 3/8" LF008PCSC-QT

Item Number: 0792027
Skip to product information
1 of 1
Regular price $2,828.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 3/8 inch
  • Weight: 3.6 lb
  • Lead Free* cast copper silicon alloy body
  • Spill-resistant design for indoor use
  • Maximum Working Pressure: 150 PSI
  • Minimum Working Pressure: 8 PSI
  • Temperature Range: 33°F - 180°F
  • Satin Chrome Finish
  • Modular cartridge for ease of service

Description

The Watts 3/8" LF008PCQT Health Hazard, Anti-Siphon, Spill-Resistant Backflow Preventer is designed for indoor point-of-use applications to prevent contaminated water from re-entering the potable water supply. Featuring lead-free cast copper silicon alloy construction and a satin chrome finish, this 3/8-inch device is ideal for general plumbing or equipment installations. It offers a spill-resistant design, operates up to 150 PSI, and includes an internal polymer coating and Tee handles. Its compact, modular cartridge design ensures durability and ease of service while complying with relevant health and safety standards. Item number 0792027.

Help Me Connect

Installation Guidance

  • For factory-installed deck/machine mounted applications, the critical level of the backflow preventer must be not less than 1 inch (25mm) above the flood rim.
  • For general plumbing applications, the critical level must be a minimum of 6 inches (150mm) above the flood rim.
  • A strainer is recommended to be installed ahead of the backflow preventer to prevent fouling of the check assembly and spillage.
  • Do not install in concealed locations or areas where water leakage due to normal wear of the internal parts could cause damage.

Warranty Information

Limited Warranty:
Watts (the "Company") warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.
View full details

Collapsible content

Additional Details

The Watts 3/8" LF008PCQT Series Anti-Siphon, Spill-Resistant Vacuum Breaker Backflow Preventer is designed for indoor point-of-use applications to prevent backsiphonage of polluted water into the potable water supply. This lead-free device features a Lead Free* cast copper silicon alloy body with a satin chrome finish, making it ideal for indoor use on machines or equipment in general plumbing applications. It protects against spillage during start-up or operation.

Key Features

  • Standardly supplied with internal polymer coating.
  • Equipped with Tee handles for easy shutoff.
  • Spill-resistant design for indoor use.
  • Features a modular cartridge for ease of service.
  • Vent utilizes an O-ring for reliable operation.
  • Includes a thermoplastic check and float assembly valve, stainless steel springs, and a molded diaphragm to separate the air inlet from the potable water supply, preventing spillage.
  • Compact, space-saving design.

Specifications

  • Body Material: Lead Free* Cast Copper Silicon Alloy
  • Size: 3/8 inch
  • End Connections: Female NPT Ball Valve shutoffs
  • Maximum Working Pressure: 150 PSI (10.3 bar)
  • Minimum Working Pressure: 8 PSI (55.2 kPa)
  • Temperature Range: 33°F - 180°F (0.5°C – 83°C)
  • Springs Material: Stainless steel
  • Bonnet Material: PPO
  • Vent Disc Material: EPDM
  • Disc Holder Material: PPO
  • Check Disc Material: Silicone rubber
  • Finish: Satin Chrome

Certificates & Approvals

  • IAPMO approved
  • ASSE 1056
  • CSA B64.1.2

FAQs

What is the primary purpose of the Watts 3/8" LF008PCQT?

It is designed to prevent contaminated water from flowing backward into the potable water supply due to backsiphonage, specifically for indoor point-of-use applications.

What material is the body of this backflow preventer made from?

The body is constructed from Lead Free* cast copper silicon alloy, ensuring durability and compliance with lead-free standards. It also features a satin chrome finish.

What are the maximum and minimum operating pressures for this device?

The maximum working pressure is 150 PSI (10.3 bar), and the minimum working pressure is 8 PSI (55.2 kPa).

Can this backflow preventer be used outdoors?

No, the Watts LF008PCQT is specifically designed for indoor use, as indicated by its spill-resistant design for indoor applications.

How does the "spill-resistant" feature work?

The spill-resistant design is achieved through a molded diaphragm that separates the air inlet from the potable water supply, preventing any spillage during start-up or operation.