10 4000SS-DOSY-FxG-FS

Item Number: F0694017
Skip to product information
1 of 1
Regular price $41,138.24
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 10 inch
  • Weight: 805.0 lb
  • Assembly Type: Reduced Pressure Zone (RPZ)
  • Body Material: 300 Series Stainless Steel
  • Integrated Flood Sensor with SentryPlus Alert® Technology
  • OSY Resilient Seated Gate Valves
  • Flanged Inlet x Grooved Outlet Connections
  • Maximum Working Pressure: 175 PSI
  • Approved by AWWA, ASSE, CSA, FM, and UL

Description

The 10 inch Ames Fire & Waterworks Series 4000SS is a reduced pressure zone backflow preventer assembly designed to protect potable water supplies from health-hazard cross-connections. It features a lightweight 300 Series stainless steel body, domestic OSY gate valves with a flanged inlet and grooved outlet, and a patented cam-check assembly for maximum flow at low pressure drop. An integrated flood sensor with SentryPlus Alert technology detects excessive water discharge, offering notification capabilities when paired with an optional connection kit. This compact, corrosion-resistant unit is rated for 175 PSI maximum working pressure. Item number F0694017.

Help Me Connect

This 10 inch Series 4000SS Reduced Pressure Zone Assembly features specific connection types for installation.

  • The inlet connection is flanged, designed to connect to compatible flanged piping.
  • The outlet connection is grooved, designed to connect to compatible grooved piping.
  • It includes domestic outside stem and yoke (OSY) resilient seated gate valves for isolation, which are UL Classified and FM Approved.
  • The integrated flood sensor can be activated with an add-on connection kit for BMS, cellular communication, or the Sensor Control Monitor for BAS/Modbus/Wi-Fi integration.
View full details

Collapsible content

Additional Details

This 10 inch Series 4000SS reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of contaminated water into the potable water supply due to backsiphonage and backpressure.

It is ideal for protection at cross-connections identified as health hazard applications and from other contaminants found at the service line entrance.

Key Features

  • Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • Includes domestic outside stem and yoke (OSY) resilient seated gate valves for shutoff.
  • Flanged inlet connection and grooved outlet connection for versatile installation.
  • Stainless steel body provides long-term corrosion resistance and maximum strength.
  • Half the weight of competitive designs, reducing installation and shipping costs.
  • Short lay length and compact construction allow for easy retrofitting and smaller enclosures.
  • Cam-check assembly ensures maximum flow at low pressure drop.
  • Stainless steel relief valve with a balanced rolling diaphragm eliminates sliding seals and lowers maintenance costs.

An add-on connection kit is required to activate the flood sensor's alert feature. Without the connection kit, the flood sensor is a passive component with no communication. Watts® is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.

Specifications

General

  • Size: 10 inch
  • Assembly Type: Reduced Pressure Zone (RPZ)
  • Body Material: 300 Series Stainless Steel
  • Internal Metal Parts: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Main Valve Body Material: 300 Series Stainless Steel
  • Connection Type: Flanged Inlet x Grooved Outlet
  • Shutoff Valves: Outside Stem and Yoke (OSY) Resilient Seated Gate Valves
  • Flood Detection: Integrated Flood Sensor with SentryPlus Alert® Technology
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C - 43°C)
  • Flange Dimension: AWWA Class D

Dimensions (Approximate)

  • Length (A): 55 3/4 inch (1416 mm)
  • Height (C, OSY): 45 3/4 inch (1162 mm)
  • Width (D): 23 13/16 inch (605 mm)
  • Depth (G): 12 1/2 inch (318 mm)
  • Length (L): 15 inch (381 mm)
  • Height (M): 29 1/2 inch (749 mm)
  • Width (N): 26 inch (660 mm)
  • Depth (P): 18 1/2 inch (470 mm)
  • Weight with Gates: 773 lbs (351 kg)
  • Weight without Gates: 189 lbs (86 kg)

Certificates & Approvals

  • AWWA C511-92
  • ASSE 1013
  • CSA B64.5
  • FM Approved (OSY only)
  • UL Classified (OSY only)

FAQs

What is the primary purpose of the Ames 4000SS backflow preventer?

Its primary purpose is to protect potable water supplies from contamination by preventing the reverse flow of hazardous materials due to backsiphonage or backpressure from health-hazard cross-connections.

What type of shutoff valves are included with this 10 inch assembly?

This 10 inch assembly includes domestic Outside Stem and Yoke (OSY) resilient seated gate valves, which are UL Classified and FM Approved.

How does the flood sensor work and what is required to activate it?

The integrated SentryPlus Alert® flood sensor detects excessive water discharge from the relief valve. To activate its notification features, an optional add-on connection kit (BMS, cellular, or Sensor Control Monitor for BAS/Wi-Fi) is required.

What are the connection types for the 10 inch 4000SS-DOSY-FxG-FS backflow preventer?

This specific model features a flanged inlet connection and a grooved outlet connection for installation into piping systems.

What is the maximum operating pressure and temperature range for this device?

The maximum operating pressure for this backflow preventer is 175 PSI (12.1 bar), and it is designed for a temperature range of 33°F to 110°F (0.5°C to 43°C).