10 LF880V-LG RP-FS

Item Number: F122950
Skip to product information
1 of 1
Regular price $33,415.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • Nominal Size: 10 inch
  • Weight: 731.0 lb
  • Type: Lead Free Reduced Pressure Zone Backflow Preventer Assembly
  • Body Material: Ductile Iron with ArmorTek Epoxy Coating
  • Corrosion Resistance: Limits MIC and exposed metal substrate corrosion
  • Relief Valve Seat and Check Components: Stainless Steel
  • Monitoring: Flood sensor with SentryPlus Alert technology
  • Connectivity: Compatible with BMS, cellular, Modbus, Wi-Fi via Sensor Control Monitor
  • Configuration: N-Pattern design, Less Shutoffs

Description

The 10 inch FEBCO LF880V-LG is a lead free ductile iron reduced pressure zone backflow preventer assembly designed for high hazard fluid protection in industrial water services. It features a patented 3-part ArmorTek epoxy coating system to resist microbial induced and exposed metal corrosion, ensuring extended durability. Stainless steel components are used for the relief valve seat and check valves. This assembly includes a SentryPlus Alert flood sensor for detecting continuous relief valve discharge, with options for integration into existing building management systems via various communication methods. It is supplied without shutoff valves in an N-Pattern configuration. Item number F122950.

Help Me Connect

This 10 inch backflow preventer assembly features a configurable N-Pattern design. It is supplied without shutoff valves, allowing for customization to specific installation requirements.

For advanced monitoring, the integrated flood sensor with SentryPlus Alert(R) technology can be connected to an optional add-on connection kit (sold separately). These kits allow the sensor to relay alerts for potential flooding events. Connection options include:

  • Building Management Systems (BMS)
  • Cellular communication
  • Sensor Control Monitor for integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa(R) platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 10 inch lead free MasterSeries(R) reduced pressure zone backflow preventer assembly, without shutoff valves, is designed to protect water services from high hazard (toxic) fluids in industrial and other applications.

It features advanced corrosion resistance and smart monitoring capabilities.

Key Features

  • Lead free ductile iron body construction with patented 3-part ArmorTek(R) epoxy coating for superior corrosion resistance.
  • Coating system specifically designed to limit both microbial induced (MIC) and exposed metal substrate corrosion.
  • Includes a stainless-steel relief valve seat and stainless-steel check components for enhanced durability and performance.
  • Configurable N-Pattern design for versatile installation.

Advanced Monitoring & Alerts

  • Equipped with a flood sensor and SentryPlus Alert(R) technology to detect continuous or excessive water discharge from the relief valve.
  • Supports integration with an add-on connection kit (not included) for extended flood monitoring.
  • When paired with a compatible connection kit, the sensor relays alerts for potential flooding events.
  • Connects via the Sensor Control Monitor to integrate with Building Automation Systems (BAS) using RS-485 Modbus or the Nexa(R) platform through Wi-Fi connectivity for maintenance alerts.

Components Included

  • Lead free body
  • Test cocks
  • Spring loaded check valves
  • Pressure differential relief valve
  • Flood sensor with SentryPlus Alert technology

Specifications

General

  • Product Type: Reduced Pressure Zone Backflow Preventer Assembly
  • Nominal Size: 10 inch
  • Connection Type: Flanged
  • Configuration: Less Shutoffs
  • Pattern: N-Pattern

Materials

  • Body Material: Lead Free Ductile Iron
  • Body Coating: Patented 3-part ArmorTek(R) Epoxy Coating
  • Relief Valve Seat Material: Stainless Steel
  • Check Components Material: Stainless Steel

Features

  • Corrosion Resistance: Limits Microbial Induced (MIC) and Exposed Metal Substrate Corrosion
  • Sensing Technology: Flood Sensor with SentryPlus Alert(R) Technology
  • Alert Integration: Compatible with BMS, Cellular Communication, Sensor Control Monitor (for BAS via RS-485 Modbus or Nexa(R) Wi-Fi)

Certificates & Approvals

  • Lead Free: Yes

FAQs

What type of fluids does this backflow preventer protect against?

This 10 inch lead free reduced pressure zone backflow preventer assembly is designed to protect against high hazard (toxic) fluids in water services for industrial installations and applications.

What kind of corrosion resistance does the ArmorTek coating provide?

The patented 3-part ArmorTek epoxy coating system is specifically designed to limit both microbial induced (MIC) corrosion and exposed metal substrate corrosion, enhancing the assembly's lifespan.

Does this assembly include shutoff valves?

No, this 10 inch backflow preventer assembly is supplied without shutoff valves, allowing for flexible integration into existing piping systems.

What is the function of the integrated flood sensor?

The integrated flood sensor with SentryPlus Alert technology detects continuous or excessive water discharges from the relief valve, providing early warning for potential flooding events when connected to an optional kit.

How can the flood sensor alerts be integrated with building systems?

When paired with an add-on connection kit (sold separately), the flood sensor can integrate with Building Management Systems (BMS), cellular communication, or a Sensor Control Monitor for BAS integration via RS-485 Modbus or the Nexa platform through Wi-Fi.