Brand - Febco

  • Product Type: Reduced Pressure Zone Detector Assembly (Type II)
  • Weight: 513.0 lb
  • Size: 10 inch
  • Lead Free: Yes (less than 0.25% lead by weight)
  • Body Material: Ductile iron Grade 65-45-12 with ArmorTek® coating
  • Max. Working Pressure: 175 PSI
  • Temperature Range: 33°F - 140°F (0.5°C – 60°C)
  • Flood Detection: SentryPlus Alert® technology on relief valve
  • Bypass Meter: Gallons Per Minute (GPM)
  • Certifications: ASSE 1047, UL Classified, FM Approved, IAPMO/CUPC, AWWA C511, CSA B64.4

Description

The 10 inch Lead Free MasterSeries LF886V Reduced Pressure Zone Detector Backflow Preventer Assembly is designed for high hazard/toxic applications to protect potable water systems from backpressure and backsiphonage. This N-pattern assembly, provided without shutoff valves, features a durable ductile iron body with patented ArmorTek advanced epoxy coating for superior corrosion resistance and extended valve life. It includes stainless steel relief valve seat and check components for maximum performance. An integrated SentryPlus Alert flood sensor detects excessive relief valve discharge, relaying alerts when activated by a connection kit. Equipped with a Gallons Per Minute (GPM) metered bypass to detect leaks, it complies with ASSE 1047, UL Classified, FM Approved, and AWWA C511 standards. Item number F683203.

Help Me Connect

Flood Sensor Activation

  • To activate the integrated flood sensor, an add-on connection kit is required. Without this kit, the sensor operates as a passive component.
  • Available connection kit options include:
    • Integration with BMS (Building Management System).
    • Cellular network communication.
    • The Sensor Control Monitor, which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 10 inch Lead Free MasterSeries® LF886V N pattern Reduced Pressure Zone Detector Backflow Preventer assembly is designed to protect potable drinking water systems against backpressure and backsiphonage conditions for high hazard/toxic applications in accordance with Local Governing Water Utility Codes. It is primarily used in industrial installations.

This assembly, supplied without shutoff valves, features a durable ductile iron body, replaceable stainless steel check seats, a gallons per minute (GPM) metered bypass, and ball valve test cocks. The ductile iron body is fused with patented 3-part ArmorTek® advanced epoxy coating for superior corrosion resistance against microbial-induced corrosion (MIC) and protection of exposed metal substrates. It includes a stainless-steel relief valve seat and stainless steel check components for maximum performance and durability, providing extended valve life and reliability.

Key Features

  • Ductile iron valve body design with ArmorTek® coating technology to resist corrosion of internals.
  • Stainless steel relief valve seat and stainless steel check components for maximum performance and durability.
  • Inline serviceable assembly; no special tools required.
  • Captured modular spring assembly.
  • Reversible and replaceable discs.
  • Field replaceable seats.
  • Modular and repairable pressure differential relief valve.
  • Clapper check assembly with a captured O-ring design.

Auxiliary Bypass Features

  • Compact design; remains in main valve assembly profile.
  • Inline serviceable 3/4 inch check assembly; no special tools required.
  • Field replaceable seat and disc.
  • Designed to detect potential underground water leaks and unauthorized water usage.

Flood Detection System

  • Integrated SentryPlus Alert® flood sensor technology on the relief valve to detect excessive water discharges.
  • Relays a signal to trigger a multichannel alert (call, email, text) to notify personnel about potential flooding when activated by an add-on connection kit.

Watts® is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.

Specifications

  • Product Type: Reduced Pressure Zone Detector Assembly (Type II)
  • Size: 10 inch
  • Pattern: N-Pattern (Standard Orientation)
  • Lead Free: Yes (wetted surface contains less than 0.25% lead by weight)
  • Application: High Hazard/Toxic, Potable Water Systems
  • Bypass Meter: Gallons Per Minute (GPM)
  • Flood Detection: SentryPlus Alert® Technology, Sensor on relief valve

Materials

  • Main Valve Body: Ductile iron Grade 65-45-12
  • Relief Valve Body: Ductile iron Grade 65-45-12
  • Coating: ArmorTek® powder coating (internal and external surfaces)
  • Check Seats: Stainless steel
  • Relief Valve Seat: Stainless steel
  • Disc Holder: Stainless steel
  • Elastomer Disc: Silicone
  • Spring: Stainless steel
  • Clamp: AWWA C606

Pressure - Temperature

  • Max. Working Pressure: 175 psi (12.1 bar)
  • Min. Working Pressure: 20 psi (1.4 bar)
  • Hydrostatic Test Pressure: 350 psi (24.1 bar)
  • Hydrostatic Safety Pressure: 700 psi (48.3 bar)
  • Temperature Range: 33°F - 140°F (0.5°C – 60°C) continuous

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • ASSE 1047
  • UL Classified (US & Canada)
  • FM Approved
  • IAPMO/CUPC
  • AWWA Standard C511 Compliant
  • CSA B64.4
  • End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange

FAQs

What is the primary purpose of this backflow preventer assembly?

This 10 inch Lead Free MasterSeries LF886V assembly is designed to protect potable water systems from contamination caused by backpressure and backsiphonage of high hazard/toxic fluids. It is typically used in industrial settings where local codes mandate such protection.

What is ArmorTek® coating and why is it important?

ArmorTek® is a patented three-part advanced epoxy system applied to the ductile iron body of the backflow preventer. It is engineered to resist microbial-induced corrosion (MIC) and protect exposed metal substrates, significantly enhancing the assembly's durability and extending its service life.

Does this assembly include shutoff valves?

No, this specific model (LF886V-LG) is supplied without shutoff valves. Shutoff valves are necessary for isolation during maintenance or in specific installations and must be purchased separately.

How does the flood sensor function?

The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. To activate its alerting capabilities, an add-on connection kit (sold separately) is required, which then allows it to relay signals for multichannel alerts about potential flooding.

What is the maximum operating pressure and temperature range for this device?

The maximum working pressure for this backflow preventer is 175 psi (12.1 bar). It is designed to operate continuously within a temperature range of 33°F to 140°F (0.5°C to 60°C).