10 LF886WZ-DOSY-LM-FS

Item Number: F8007407
Skip to product information
1 of 1
Regular price $61,130.26
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • 10 inch nominal size
  • Weight: 987.0 lb
  • N-Pattern (Horizontal) assembly
  • Ductile Iron body with ArmorTek® coating
  • OSY shutoff valves (UL Classified and FM Approved)
  • Stainless steel check seats and relief valve seat
  • Flood sensor with SentryPlus Alert® technology
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F - 140°F

Description

This 10 inch FEBCO MasterSeries reduced pressure detector backflow preventer assembly (RPDA) is engineered to protect potable water supplies from high hazard backpressure and backsiphonage conditions in industrial applications. Featuring a ductile iron body with ArmorTek® coating for corrosion resistance and stainless steel relief valve and check components, this assembly ensures maximum performance and extended valve life. It includes a SentryPlus Alert® flood sensor for detecting continuous discharge. This N-Pattern (horizontal) unit is UL Classified, FM Approved, ASSE 1047, AWWA C511, and CSA B64.4 compliant, operating up to 175 PSI.

Help Me Connect

This FEBCO 10 inch backflow preventer assembly features a longer lay-length, making it suitable as a drop-in replacement for competitor Z-pattern valves. Its N-Pattern (horizontal) orientation ensures compatibility with relevant piping configurations.

The integrated flood sensor with SentryPlus Alert® technology requires an add-on connection kit for activation and communication. Connection kit options enable integration with Building Automation Systems (BAS) via RS-485 Modbus, cellular communication, or the Nexa® platform through Wi-Fi, allowing for enhanced flood monitoring and alerts.

View full details

Collapsible content

Additional Details

This 10 inch lead free MasterSeries® reduced pressure detector backflow preventer assembly (RPDA) protects against high hazard (toxic) fluids in water services to industrial installations and applications.

It is designed to prevent backpressure and backsiphonage conditions, featuring a longer lay-length for drop-in replacement of competitor’s Z-pattern valves.

Key Features

  • Equipped with a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • ArmorTek® powder coating on ductile iron body for integrated protection against electrochemical corrosion and microbial-induced corrosion.
  • Combines a stainless-steel relief valve seat and stainless-steel check components for maximum performance and durability.
  • Features replaceable stainless steel check seats, a bypass line with a 5/8 inch x 3/4 inch water meter, and ball valve test cocks.
  • Supplied with domestic OSY (Outside Stem and Yoke) shutoff valves that are UL Classified and FM Approved.
  • N-Pattern (horizontal) assembly designed for competitor Z-pattern drop-in replacement.

IMPORTANT NOTICE: An add-on connection kit is required to activate the flood sensor. Without this kit, the flood sensor is a passive component and does not communicate with any other device. Use of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide proper drainage in the event of a discharge. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

Specifications

General

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Nominal Size: 10 inch
  • Assembly Pattern: N-Pattern (Horizontal)

Materials

  • Main Valve Body: Ductile Iron Grade 65-45-12
  • Relief Valve Body: Ductile Iron Grade 65-45-12
  • Coating: ArmorTek Powder Coating
  • Shutoff Valves: OSY Resilient Wedge Gate Valve (UL Classified and FM Approved)
  • Check Seats: Stainless Steel
  • Relief Valve Seat: Stainless Steel
  • Disc Holder: Stainless Steel
  • Elastomer Disc: Silicone
  • Spring: Stainless Steel
  • Clamp: AWWA C606

Pressure & Temperature

  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Minimum Working Pressure: 20 PSI (1.4 bar)
  • Hydrostatic Test Pressure: 350 PSI (24.1 bar)
  • Hydrostatic Safety Pressure: 700 PSI (48.3 bar)
  • Temperature Range: 33°F - 140°F (0.5°C ~ 60°C) continuous

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • ASSE 1047
  • UL Classified (US & Canada)
  • FM Approved
  • IAPMO/CUPC
  • AWWA Standard C511 Compliant
  • CSA B64.4
  • End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange

FAQs

What is the primary function of this backflow preventer?

This backflow preventer is designed to protect potable water supplies from contamination by high hazard (toxic) fluids caused by backpressure and backsiphonage conditions in industrial water services.

What is the "ArmorTek® coating"?

ArmorTek® is a specialized powder coating applied to the ductile iron body of the backflow preventer. It provides integrated protection against electrochemical corrosion and microbial-induced corrosion.

Does this assembly include shutoff valves?

Yes, this assembly comes with domestic OSY (Outside Stem and Yoke) shutoff valves, which are UL Classified and FM Approved.

How does the flood sensor work, and what is needed to activate it?

The integrated flood sensor with SentryPlus Alert® technology detects continuous discharge from the relief valve. To activate its communication features and relay alerts, an add-on connection kit (sold separately) is required.

What is the maximum operating pressure and temperature range?

This backflow preventer has a maximum working pressure of 175 PSI (12.1 bar) and can operate continuously in a temperature range of 33°F to 140°F (0.5°C to 60°C).