Brand - Watts

  • Size: 2 1/2 inch
  • Body Material: Stainless Steel
  • Lead Free: Yes
  • Assembled without shutoff valves
  • Flood sensor with SentryPlus Alert technology
  • Maximum Operating Pressure: 175 PSI
  • Temperature Range: 33°F-110°F
  • Certifications: ASSE 1013, CSA B64.4, UL, FM

Description

The Watts 2 1/2 inch 994-LF-FS is a lead-free reduced pressure zone (RPZ) backflow preventer designed to protect water systems from reverse flow in health hazard applications. It features a compact, durable stainless steel body, test cocks, and torsion spring check valves, ensuring reliability and easy maintenance. This model is assembled without shutoff valves, ideal for installations with existing isolation valves. An integrated flood sensor with SentryPlus Alert technology detects excessive relief valve discharges, with remote notification available via an optional add-on connection kit. Rated for continuous operation up to 175 PSI and certified by ASSE 1013, CSA B64.4, UL, and FM.
View full details

Collapsible content

Additional Details

This 2 1/2 inch lead free reduced pressure zone (RPZ) assembly backflow preventer is designed to prevent the reverse flow of liquids due to backpressure or backsiphonage, particularly where a potential health hazard exists.

Its compact, modular design facilitates easy maintenance with a single access cover for in-line repairs. This assembly features a short lay length stainless steel body, test cocks, a corrosive-resistant stainless steel bottom-mounted relief valve, and torsion spring check valves.

Flood Sensor Technology

  • Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • When activated through an add-on sensor connection kit, the flood sensor relays a signal that triggers notification of potential flooding to service personnel.
  • The add-on sensor connection kit is available for building management systems and cellular communication.

Warning: Without an add-on connection kit, the flood sensor is a passive component that does not communicate with any other device.

Key Features

  • Stainless steel body provides long term corrosion resistance and maximum strength.
  • Stainless steel body is half the weight of competitive designs, reducing installation and shipping costs.
  • Short end-to-end dimensions make retrofit easy.
  • Bottom mounted relief valve reduces clearance requirements when installed against an outside wall.
  • Torsion spring check valves provide maximum flow at low pressure drop.
  • No special tools required for servicing.
  • Compact construction allows for smaller enclosures.
  • Sensor on relief valve for flood detection.
  • Assembled without shutoff valves.
  • Designed for health hazard applications.

Specifications

  • Product Type: Reduced Pressure Zone (RPZ) Backflow Preventer
  • Size: 2 1/2 inch
  • Lead Free: Yes
  • Shutoff Valves: Less Shutoff / Assembled without Shutoff Valves
  • Body Material: Stainless Steel
  • Main Valve Body Material: 300 Series Stainless Steel
  • Internal Metal Parts: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Relief Valve: Corrosive Resistant Stainless Steel, Bottom Mounted
  • Check Valves: Torsion Spring
  • Flood Sensor: Yes, with SentryPlus Alert Technology
  • Temperature Range: 33°F-110°F (0.5°C-43°C) continuous
  • Maximum Operating Pressure: 175 psi (12.1 bar)

Certificates & Approvals

  • ASSE 1013
  • CSA B64.4
  • UL Classified
  • FM Approved

FAQs

What is the primary function of the Watts 994-LF-FS backflow preventer?

The primary function is to prevent the reverse flow of non-potable or contaminated water into the potable water supply, especially in applications where a potential health hazard exists due to backpressure or backsiphonage.

Does this backflow preventer come with shutoff valves?

No, this Watts 994-LF-FS model is assembled without shutoff valves. It is designed for installations where isolation shutoff valves are provided separately or already exist.

What is the purpose of the flood sensor with SentryPlus Alert technology?

The flood sensor with SentryPlus Alert technology detects excessive water discharges from the relief valve. When connected to an optional add-on sensor kit, it can send notifications to alert personnel of potential flooding, helping to prevent property damage and operational downtime.

What material is the body of this backflow preventer made from?

The body of the Watts 994-LF-FS backflow preventer is constructed from durable stainless steel. This material provides excellent corrosion resistance and maximum strength, while also contributing to a lighter unit weight.

What is the maximum operating pressure and temperature range for this device?

This backflow preventer has a maximum operating pressure of 175 psi (12.1 bar). It is designed to operate continuously within a temperature range of 33°F to 110°F (0.5°C to 43°C).