2.5 957-OSY-GxG-FS

Item Number: F112062
Skip to product information
1 of 1
Regular price $7,470.74
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Product Type: Reduced Pressure Zone Assembly
  • Weight: 225.0 lb
  • Nominal Size: 2.5 inch
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: OSY Resilient Seated Gate
  • Connections: Grooved Inlet x Grooved Outlet
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 140°F
  • Flood Sensor: SentryPlus Alert® technology

Description

The Watts Series 957 2.5 inch Reduced Pressure Zone Assembly Backflow Preventer safeguards potable water systems from contamination by backsiphonage and backpressure in health hazard applications. This lead-free unit features 304 stainless steel housing, UL and FM Approved OSY resilient seated gate valves, and grooved inlet and outlet connections. It operates effectively within a temperature range of 33°F to 140°F and handles a maximum working pressure of 175 psi. An integrated flood sensor with SentryPlus Alert® technology detects excessive relief valve discharge, relaying alerts when paired with an add-on connection kit to prevent potential flooding. Item number F112062.

Help Me Connect

Connections

  • This Watts Series 957 backflow preventer connects to your pipeline using grooved inlet and outlet connections, allowing for integral pipeline adjustment.

Flood Sensor Connectivity

  • To activate flood monitoring, an add-on sensor connection kit is required.
  • This kit enables compatibility with Building Management Systems (BMS), cellular network communication, and the Sensor Control Monitor.
  • The Sensor Control Monitor allows integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.
View full details

Collapsible content

Additional Details

The Watts Series 957 2.5 inch Reduced Pressure Zone Assembly Backflow Preventer provides critical protection for potable water systems against contamination from backsiphonage and backpressure, commonly used in health hazard applications. This lead-free assembly features UL Classified and FM Approved OSY (Outside Stem and Yoke) resilient seated gate valves and an integrated flood sensor for enhanced monitoring.

The flood sensor detects excessive water discharges from the relief valve. When activated with an add-on connection kit, this sensor can relay signals to facility personnel, enabling prompt corrective action to limit potential flooding and costly damage. Connection kit options include compatibility with BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Key Features

  • Protects potable water systems from contamination due to backsiphonage or backpressure.
  • Incorporates a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for durability.
  • Equipped with UL Classified and FM Approved OSY (Outside Stem and Yoke) resilient seated gate valves.
  • Features positive seated torsion spring check modules and a bottom-mounted differential pressure relief valve.
  • Designed with groove fittings for integral pipeline adjustment and unmatched ease of serviceability.
  • Wetted surfaces contain less than 0.25% lead by weight, making it a Lead Free* product.
  • Extremely compact design, up to 70% lighter than traditional designs.

Connections

  • Inlet: Grooved gate connection
  • Outlet: Grooved gate connection

Specifications

  • Product Type: Reduced Pressure Zone Assembly
  • Nominal Size: 2.5 inch
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Valve Type: OSY (Outside Stem and Yoke) Resilient Seated Gate Valves
  • Connections: Grooved Inlet x Grooved Outlet
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)
  • Wetted Surface Lead Content: Less than 0.25% by weight (Lead Free*)

Materials

  • Elastomers: EPDM, Silicone, Buna-N
  • Torsion Spring Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks: Lead Free* Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel

Certificates & Approvals

  • Approved by FCCCHR-USC
  • AWWA C511-97
  • ASSE 1013
  • CSA B64.4
  • CULUS Classified
  • FM Approved
  • NSF Certified to NSF/ANSI 61-G

FAQs

What is the primary function of the Watts Series 957 backflow preventer?

Its primary function is to protect potable water systems from contamination caused by backsiphonage or backpressure, particularly in health hazard applications.

What type of shutoff valves are included with this assembly?

This assembly includes UL Classified and FM Approved OSY (Outside Stem and Yoke) resilient seated gate valves for reliable shutoff.

How does the flood sensor function, and what connectivity options does it offer?

The flood sensor detects excessive water discharges from the relief valve. When an add-on connection kit is used, it can relay alerts via BMS, cellular communication, or integrate with BAS through RS-485 Modbus or the Nexa® platform via Wi-Fi.

What are the material specifications for the housing and wetted surfaces?

The housing and sleeve are constructed from 304 (Schedule 40) stainless steel. All wetted surfaces are lead-free, containing less than 0.25% lead by weight.

What are the maximum operating pressure and temperature limits for this backflow preventer?

This backflow preventer is designed for a maximum working pressure of 175 psi (12.1 bar) and operates within a temperature range of 33°F to 140°F (0.5°C to 60°C).