2.5 957NRPDA-BFG-CFM-FS

Item Number: F111656
Skip to product information
1 of 2
Regular price $9,722.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 2 1/2 inch
  • Weight: 132.0 lb
  • Type: Reduced Pressure Detector Assembly
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 140°F
  • Valve Type: UL/FM Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Flood Sensor: SentryPlus Alert Technology
  • Installation: Horizontal N-Pattern Approved

Description

The Watts 2 1/2 inch Series 957NRPDA Reduced Pressure Detector Assembly Backflow Preventer offers reliable protection against backpressure and backsiphonage contamination in potable water systems. Constructed with a 304 (Schedule 40) stainless steel housing, it features an extremely compact, lightweight design ideal for horizontal N pattern installations. This assembly includes UL and FM approved grooved gear operated butterfly valves with tamper switches, a metered bypass for leak detection, and a SentryPlus Alert flood sensor to detect relief valve discharges. The flood sensor integrates with various communication kits for remote monitoring and alerts, making it suitable for fire protection systems. Item number F111656.

Help Me Connect

Installation Orientation

  • This Watts 957NRPDA backflow preventer is specifically approved for horizontal N pattern installation.

Flood Sensor Connectivity

  • The integrated flood sensor requires an add-on connection kit (sold separately) for activation and communication.
  • Connection kit options allow for integration with Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor which enables alerts to BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.
View full details

Collapsible content

Additional Details

The Watts 2 1/2 inch Series 957NRPDA Reduced Pressure Detector Assembly Backflow Preventer helps prevent the reverse flow of liquids due to backpressure or backsiphonage where potential health hazards exist. This assembly is designed for horizontal N pattern installation and monitors unauthorized water use, as well as providing protection against contamination in potable water systems.

Flood Detection System

  • Includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve.
  • The sensor relays a signal for notification to facility personnel, limiting flooding and costly damage.
  • An add-on connection kit is required to activate the flood sensor and enable communication. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.

Features

  • Extremely compact design, allowing for smaller enclosures.
  • Approximately 70% lighter than traditional designs.
  • Housing and sleeve constructed from 304 (Schedule 40) stainless steel.
  • Groove fittings allow integral pipeline adjustment.
  • Patented torsion spring check provides lowest pressure loss.
  • Unmatched ease of serviceability with replaceable check disc rubber.
  • Includes UL Classified and FM Approved grooved gear operated butterfly valves with tamper switch.
  • Bottom mounted cast stainless steel relief valve.
  • Metered bypass with a cubic foot per minute meter to detect leakage or theft of water from the fire sprinkler system.

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

Dimensions & Weight

  • Size: 2 1/2 inch

Performance

  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)

Materials

  • Housing & Sleeve: 304 (Schedule 40) stainless steel
  • Elastomers: EPDM, silicone, Buna 'N'
  • Torsion Spring Checks: Noryl®, stainless steel
  • Check Discs: Reversible silicone or EPDM
  • Test Cocks Body: Lead Free* bronze
  • Pins & Fasteners: 300 Series stainless steel
  • Springs: Stainless steel

Certificates & Approvals

  • AWWA: C511-97
  • ASSE: 1047
  • CSA: B64.4
  • UL: Classified
  • FM: Approved (with BFG valves)
  • FCCCHR-USC: Approved (excluding 10" N-pattern, 6" & 10" Z-pattern installations)

FAQs

What is the primary purpose of the Watts 957NRPDA backflow preventer?

The primary purpose is to protect potable water systems from contamination due to backpressure or backsiphonage, particularly in health hazard applications, and to monitor unauthorized water use from fire protection systems.

Is this backflow preventer approved for all installation orientations?

No, this specific model (957NRPDA) is approved for horizontal N pattern installation only. Consult local codes and authorities for specific installation requirements.

How does the flood sensor function, and what is needed to activate it?

The flood sensor detects excessive water discharges from the relief valve and can relay signals for notification. To activate its communication features, an add-on connection kit (sold separately) is required, offering options for BMS, cellular, or Wi-Fi integration.

What are the key materials used in the construction of this assembly?

The housing and sleeve are made from 304 (Schedule 40) stainless steel. Elastomers include EPDM, silicone, and Buna 'N'. Test cocks feature Lead Free bronze bodies, and other components like pins, fasteners, and springs are 300 series stainless steel.

What is the maximum operating pressure and temperature range for this device?

This backflow preventer has a maximum working pressure of 175 psi (12.1 bar). The operational temperature range is 33°F to 140°F (0.5°C to 60°C).