Brand - Watts

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Weight: 309.0 lb
  • Nominal Size: 2 1/2 inch
  • Shutoff Valves: Non-Rising Stem (NRS) Gate Valves
  • Housing Material: 304 Stainless Steel
  • Flood Sensor: SentryPlus Alert® Technology
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 140°F
  • Lead Free*: Wetted surface contains less than 0.25% lead by weight

Description

The Watts 2 1/2 inch Series 957 Reduced Pressure Zone (RPZ) backflow preventer is designed to protect potable water systems from contamination due to backpressure or backsiphonage in health hazard applications. This compact and lightweight assembly features 304 stainless steel housing, non-rising stem gate valves, and a cast iron flanged strainer. A built-in SentryPlus Alert® flood sensor detects excessive relief valve discharge, with alerts configurable via an optional connection kit for BMS, cellular, or Wi-Fi integration. Approved for horizontal installation, this lead-free RPZ offers low pressure loss and ease of serviceability. Item F111825.

Help Me Connect

Installation Notes

  • This Watts Series 957 backflow preventer is approved for horizontal installation, provided the assembly is installed in accordance with the direction of the flow arrow.
  • The unit features groove couplings for ease of installation and integral pipeline alignment.
  • To activate the flood sensor's alert features, an add-on sensor connection kit is required (sold separately). These kits can enable compatibility with Building Management Systems (BMS), cellular networks, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform via Wi-Fi.
  • When installing a drain line, use 957AG air gaps and attach air gap brackets directly onto the flood sensor.
View full details

Collapsible content

Additional Details

The Watts Series 957 Reduced Pressure Zone (RPZ) backflow preventer with NRS shutoff valves and flood sensor provides protection for potable water systems against contamination from backsiphonage or backpressure, suitable for health hazard applications.

This 2 1/2 inch assembly is compact, lightweight, and features a SentryPlus Alert® flood sensor to detect excessive water discharges from the relief valve.

Key Components

  • 304 (Schedule 40) stainless steel housing and sleeve for durability.
  • Two independent torsion spring check modules with replaceable elastomer discs.
  • Bottom-mounted cast stainless steel relief valve.
  • Non-rising stem, resilient seated gate valves.
  • Cast iron flanged strainer.
  • Test cocks for easy maintenance.

Flood Sensor Technology

  • Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • Requires an add-on sensor connection kit (sold separately) to activate flood monitoring.
  • Activated sensor relays alerts for potential flooding events via BMS, cellular communication, or the Sensor Control Monitor (integrates with BAS via RS-485 Modbus or Nexa® platform via Wi-Fi).

Design & Performance

  • Extremely compact design, allowing for smaller enclosures.
  • Approximately 70% lighter than traditional designs for easier installation.
  • Groove couplings facilitate integral pipeline adjustment and ease of installation.
  • Patented torsion spring checks provide the lowest pressure loss.
  • Unmatched ease of serviceability.
  • Wetted surfaces of this product contain less than 0.25% lead by weight, meeting Lead Free* requirements.

Specifications

  • Product Type: Reduced Pressure Zone (RPZ) Backflow Preventer
  • Nominal Size: 2 1/2 inch
  • Model Series: 957NRS-S-FS
  • Flood Sensor: Yes, with SentryPlus Alert® technology

Materials

  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: Non-Rising Stem (NRS), Resilient Seated Gate Valves
  • Strainer: Cast Iron Flanged
  • Check Disc Rubber: Replaceable Elastomer
  • Check Discs: Reversible Silicone or EPDM
  • Elastomers: EPDM, Silicone, Buna-N
  • Torsion Spring Checks: Noryl®, Stainless Steel
  • Test Cocks: Lead Free* Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Relief Valve: Cast Stainless Steel, Bottom Mounted

Performance Ratings

  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)

Certificates & Approvals

  • Approved By: Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • Standard: AWWA C511-97
  • Standard: ASSE 1013
  • Standard: CSA B64.4
  • Certified To: NSF/ANSI 61-G (Lead Free)

FAQs

What is the primary purpose of the Watts Series 957 Reduced Pressure Zone assembly?

Its primary purpose is to protect potable water systems from contamination caused by backsiphonage or backpressure, particularly in health hazard applications, in compliance with national plumbing codes.

Does this backflow preventer include a flood sensor?

Yes, it includes a SentryPlus Alert® flood sensor to detect excessive water discharges from the relief valve, helping to prevent potential flooding and costly damage.

How do I activate the flood sensor's alert features?

An add-on sensor connection kit is required to activate the flood sensor's alert features. Without this kit, the sensor is a passive component with no communication capabilities.

What materials are used in the construction of the housing and sleeve?

The housing and sleeve are constructed from durable 304 (Schedule 40) stainless steel, providing robust and corrosion-resistant performance.

What type of shutoff valves does this model use?

This particular model, the 957NRS-S-FS, features non-rising stem (NRS) resilient seated gate valves.