2.5 LF009-OSY-S-FDA-FS

Item Number: F122647
Skip to product information
1 of 1
Regular price $10,125.75
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 2 1/2 inch
  • Lead Free Construction
  • Body Material: Cast Iron
  • Shutoff Valves: UL/FM OSY Resilient Seated Gate
  • Strainer: FDA Epoxy Coated
  • Coating: ArmorTek® Advanced Epoxy System
  • Flood Sensor: SentryPlus Alert® Technology
  • Maximum Pressure: 175 PSI

Description

This 2 1/2 inch Lead Free Watts Series LF009 Reduced Pressure Zone (RPZ) backflow preventer assembly protects potable water supplies from pollution due to backsiphonage or backpressure. It features a robust cast iron body with ArmorTek® advanced epoxy coating for corrosion resistance and an FDA epoxy coated strainer. UL and FM approved OSY resilient seated gate valves ensure reliable shutoff. An integrated flood sensor with SentryPlus Alert® technology detects relief valve discharge, with optional connection kits for advanced alerts via BMS, cellular, or Wi-Fi. It is rated for 175 PSI maximum pressure and up to 140°F intermittent water temperature.

Help Me Connect

Flood Sensor Activation

  • The integrated flood sensor with SentryPlus Alert® technology requires an add-on connection kit (sold separately) to enable its alert features and communication.
  • Without the connection kit, the sensor is passive and does not communicate with other devices.

Connectivity Options

  • Connection kit options include compatibility with Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor.
  • The Sensor Control Monitor enables integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 2 1/2 inch lead free reduced pressure zone backflow preventer assembly is designed to protect potable water supplies from pollution caused by backsiphonage or backpressure.

Primary Use

  • Prevents health hazard cross-connections in continuous pressure piping applications
  • Ideal for containment at the service line entrance
  • Suitable for irrigation systems, boiler feed, and other installations requiring maximum protection

Construction & Materials

  • Cast iron body construction for 2 1/2 inch to 3 inch sizes
  • ArmorTek® patented three-part advanced epoxy coating system on iron components to resist microbial-induced corrosion (MIC) and protect exposed metal substrate
  • FDA epoxy coated strainer for durability and compliance
  • Lead Free* construction, with wetted surfaces containing less than 0.25% lead by weight

Components

  • Two in-line, independent check valves with captured springs and replaceable check seats
  • Internal relief valve for reduced installation clearances
  • UL and FM Approved outside stem and yoke (OSY) resilient seated gate valves
  • Top mounted ball valve test cocks for ease of testing

Flood Sensor Technology

  • Integrated flood sensor with SentryPlus Alert® technology detects continuous discharge from the relief valve
  • Requires an add-on connection kit (sold separately) to activate the sensor's alert features
  • Compatible with BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or Nexa® platform via Wi-Fi

Key Features

  • Compact, space-saving design
  • Single access cover and modular check construction for ease of maintenance
  • Top entry to all internals for immediate accessibility
  • Captured springs for safe maintenance
  • Replaceable seats for economical repair
  • No special tools required for servicing
  • Large body passages provide low pressure drop

Specifications

General

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Nominal Size: 2 1/2 inch
  • Series: LF009
  • Model: LF009-OSY-S-FDA-FS
  • Shutoff Type: Outside Stem and Yoke (OSY) Gate Valves
  • Strainer: FDA Epoxy Coated Strainer
  • Coating: ArmorTek® Advanced Coating System
  • Lead Free: Yes (wetted surfaces contain less than 0.25% lead)

Materials

  • Body Material: Cast Iron
  • Relief Valve Seat & Trim: Stainless Steel

Performance

  • Maximum Supply Pressure: 175 PSI (12.1 bar)
  • Continuous Water Temperature: 110°F (43°C)
  • Intermittent Water Temperature: 140°F (60°C)

Certificates & Approvals

  • USC
  • ASSE No. 1013
  • AWWA C511
  • CSA B64.4
  • IAPMO File No. 1563
  • UL Classified (with OSY gate valves)
  • FM Approved (with OSY gate valves)

FAQs

What is the primary function of the Watts LF009 Reduced Pressure Zone Backflow Preventer?

Its primary function is to protect potable water supplies by preventing polluted water from flowing back into the system due to backsiphonage or backpressure, addressing health hazard cross-connections.

What type of shutoff valves are included with this assembly?

This assembly includes UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves, which provide reliable control and isolation.

How does the ArmorTek® coating benefit the backflow preventer?

The ArmorTek® coating is a patented three-part advanced epoxy system applied to the iron components. It is engineered to reduce microbial-induced corrosion (MIC) and protect the exposed metal substrate, extending the product's lifespan.

Is a connection kit required for the flood sensor to work?

Yes, an add-on sensor connection kit is required to activate the flood sensor's alert features and communication capabilities. Without the kit, the sensor remains a passive component.

What are the water pressure and temperature limits for this 2 1/2 inch model?

This model is suitable for supply pressures up to 175 PSI (12.1 bar). It can handle continuous water temperatures up to 110°F (43°C) and intermittent temperatures up to 140°F (60°C).