2.5 LF866-OSY-GPM-FS
Item Number: F683174
1
/
of
1
Regular price
$11,966.98
Special Order
When Will it Ship:
Contact for Lead Time
Estimated transit time: 2 to 5 Business Days
Brand - Febco
Couldn't load pickup availability
- Size: 2 1/2 inch
- Weight: 218.0 lb
- Body Material: Ductile Iron
- Coating: ArmorTek Epoxy System
- Shutoff Valves: OS&Y Gate Valves
- Bypass Meter: Gallons Per Minute (GPM)
- Flood Sensor: SentryPlus Alert Technology
- Max Working Pressure: 175 PSI
- Lead Free: Yes
Description
Description
The 2 1/2 inch MasterSeries LF866 Reduced Pressure Zone Detector Backflow Preventer Assembly provides reliable protection for potable water systems against backpressure and backsiphonage in high hazard/toxic applications. Constructed from ductile iron with ArmorTek advanced epoxy coating for corrosion resistance, it features stainless steel internal components for durability. This lead-free assembly includes OS&Y shutoff valves, a gallons per minute bypass meter, and an integrated flood sensor with SentryPlus Alert technology to detect relief valve discharges and notify personnel. It complies with ASSE 1047, UL Classified, FM Approved, and AWWA C511 standards, ensuring high performance and regulatory compliance. Item number F683174.
Help Me Connect
Help Me Connect
Application & Compatibility
- This backflow preventer assembly is designed for installation on potable drinking water systems to protect against backpressure and backsiphonage, especially in high hazard/toxic applications.
- The integral flood sensor requires an add-on connection kit (available separately) for active communication and alert relay. Connection kit options include those for Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor which integrates with BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.
- End connections are compliant with ASME B16.1 Class 125 and AWWA Class D Flange standards.

Collapsible content
Additional Details
This 2 1/2 inch lead free MasterSeries LF866 Reduced Pressure Zone Detector Backflow Preventer Assembly is designed to protect potable drinking water systems from backpressure and backsiphonage conditions, particularly in high hazard/toxic industrial installations and applications.
It features a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve, providing alerts for potential flooding.
Construction & Durability
- Features a ductile iron body construction with patented ArmorTek, a three-part advanced epoxy coating system engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate.
- Combines the use of a stainless-steel relief valve seat and stainless-steel check components for maximum performance and durability.
- Inline serviceable assembly; no special tools required for servicing check modules.
- Captured modular spring assembly, reversible and replaceable discs, and field replaceable seats.
Integrated Flood Detection
- Includes a flood sensor on the relief valve to detect excessive water discharges, relaying signals for multichannel alerts (call, email, text) to notify personnel of potential flooding.
- An add-on connection kit is required to activate the flood sensor for active communication; without the connection kit, the flood sensor is a passive component. The flood sensor does not replace the need for proper drainage or compliance with installation/maintenance codes.
Auxiliary Bypass System
- Detector bypass assembly with a gallons per minute (GPM) meter and an approved check assembly.
- Designed to detect potential underground water leaks and unauthorized water usage.
- Compact design; remains in main valve assembly profile.
- Inline serviceable 3/4 inch check assembly; no special tools required.
- Field replaceable seat and disc.
Specifications
- Product Type: Reduced Pressure Zone Detector Assembly
- Size: 2 1/2 inch
- Main Valve Body Material: Ductile iron Grade 65-45-12
- Relief Valve Body Material: Ductile iron Grade 65-45-12
- Coating: ArmorTek Powder Coating
- Shutoff Valves: OSY Resilient Wedge Gate Valve
- Check Seats Material: Stainless steel
- Relief Valve Seat Material: Stainless steel
- Disc Holder Material: Stainless steel
- Elastomer Disc Material: Silicone
- Spring Material: Stainless steel
- Bypass Meter: 5/8 inch x 3/4 inch Gallons Per Minute (GPM) Water Meter
- Flood Sensor: Included (on relief valve)
Performance & Pressure Ratings
- Maximum Working Pressure: 175 psi (12.1 bar)
- Minimum Working Pressure: 20 psi (1.4 bar)
- Hydrostatic Test Pressure: 350 psi (24.1 bar)
- Hydrostatic Safety Pressure: 700 psi (48.3 bar)
- Temperature Range: 33°F - 140°F (0.5°C ~ 60°C) continuous
Certificates & Approvals
- Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
- ASSE 1047
- UL Classified (US & Canada)
- FM Approved
- IAPMO/CUPC
- AWWA Standard C511 Compliant
- End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange
- Lead Free Construction
FAQs
What is the primary function of this backflow preventer?
This assembly protects potable drinking water systems from contamination due to backpressure and backsiphonage, particularly in high hazard/toxic industrial installations and applications.
Does this backflow preventer include a flood sensor?
Yes, it includes a flood sensor on the relief valve to detect excessive water discharges. When activated with an add-on connection kit, it can relay alerts via call, email, or text.
What material is the body made from and how is it protected from corrosion?
The main valve and relief valve bodies are constructed from ductile iron Grade 65-45-12. They are protected with ArmorTek, a patented three-part advanced epoxy coating system designed to resist microbial-induced corrosion (MIC) and protect exposed metal substrates.
Are the internal components easily serviceable?
Yes, the assembly features an inline serviceable design for its check modules, captured modular spring assembly, and field-replaceable seats and discs, typically requiring no special tools for maintenance.
What type of bypass system is included with this model?
This model includes a detector bypass assembly with a 5/8 inch x 3/4 inch gallons per minute (GPM) water meter. This bypass helps detect potential underground water leaks and unauthorized water usage.