2 LF009M2-QTW/PRESS-FS

Item Number: 88004121
Skip to product information
1 of 1
Regular price $2,752.54
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 2 inch
  • Weight: 28.3 lb
  • Body Material: Lead Free Cast Copper Silicon Alloy
  • Connection Type: NPT with Viega ProPress Adaptors
  • Shutoff Valves: Quarter-Turn Full Port Ball Valves
  • Flood Detection: SentryPlus Alert Sensor
  • Max Supply Pressure: 175 PSI
  • Water Temperature Range: 33°F - 180°F
  • Easy Maintenance: Single Access Cover

Description

The Watts 2 inch Lead Free Reduced Pressure Zone Backflow Preventer Assembly is designed to protect potable water supplies from contamination caused by backsiphonage or backpressure. Featuring durable Lead Free cast copper silicon alloy construction, this assembly includes NPT connections with Viega ProPress adaptors and quarter-turn ball valve shutoffs. A SentryPlus Alert flood sensor provides early detection of excessive relief valve discharge, enhancing system safety. Its compact, modular design with a single access cover ensures easy maintenance and economical repair. This assembly is suitable for health hazard cross-connections and irrigation systems.

Help Me Connect

This 2 inch backflow preventer features NPT inlet and outlet connections, factory-installed with Viega ProPress adaptors on both ends for efficient and reliable plumbing system integration.

The integrated SentryPlus Alert flood sensor for relief valve discharge detection can be activated using an optional add-on connection kit. These kits enable communication and alerts via:

  • Building Management Systems (BMS)
  • Cellular communication
  • Sensor Control Monitor for integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 2 inch Lead Free Reduced Pressure Zone (RPZ) backflow preventer assembly is engineered to protect potable water supplies from backsiphonage and backpressure, meeting national plumbing codes and water authority requirements. It is ideal for health hazard cross-connections, service line entrances, irrigation systems, and boiler feed lines. The assembly features a compact, modular design for easy maintenance and includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve.

Key Features

  • Lead Free cast copper silicon alloy body construction for durability and compliance.
  • SentryPlus Alert flood sensor detects continuous discharge from the relief valve.
  • NPT inlet and outlet connections with pre-installed Viega ProPress adaptors.
  • Quarter-turn full port resilient seated ball valve shutoffs for reliable operation.
  • Single access cover and modular check construction facilitate ease of maintenance.
  • Top entry to all internals for immediate accessibility.
  • Captured springs for safe maintenance during servicing.
  • Internal relief valve design reduces installation clearances.
  • Replaceable seats for economical repair.
  • Includes two in-line independent check valves and four resilient seated test cocks.

An add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component with no communication. Watts is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.

Specifications

  • Product Type: Reduced Pressure Zone (RPZ) Backflow Preventer
  • Nominal Size: 2 inch
  • Body Material: Lead Free Cast Copper Silicon Alloy
  • Connection Type: NPT with Viega ProPress Adaptors
  • Shutoff Valves: Quarter-Turn Full Port Ball Valves
  • Flood Detection: SentryPlus Alert Flood Sensor (requires add-on kit for active alerts)
  • Maximum Supply Pressure: 175 PSI (12.1 bar)
  • Water Temperature Range: 33°F - 180°F (0.5° - 82°C)
  • Disc Material: Silicone Rubber (first and second check, relief valve)
  • Check Seats: Replaceable Polymer
  • Cover Bolts: Stainless Steel

Certificates & Approvals

  • USC
  • ASSE Std. 1013
  • AWWA Std. C511
  • CSA B64.4
  • IAPMO File No. 1563
  • UL Classified

FAQs

What is the primary purpose of this backflow preventer?

This 2 inch Lead Free Reduced Pressure Zone (RPZ) backflow preventer is designed to protect potable water supplies from contamination due to backsiphonage and backpressure, ensuring compliance with plumbing codes.

What type of connections does this backflow preventer have?

This assembly features 2 inch NPT (National Pipe Thread) inlet and outlet connections, which come with factory-installed Viega ProPress adaptors for easy and secure installation.

How does the flood sensor feature work?

The integrated SentryPlus Alert flood sensor detects excessive water discharges from the relief valve. To activate alerts and communication, an optional add-on connection kit is required, which can integrate with BMS, cellular, or Wi-Fi platforms.

What material is the body of this backflow preventer made from?

The body is constructed from Lead Free cast copper silicon alloy, ensuring durability and compliance with lead-free installation requirements for potable water systems.

Is this backflow preventer easy to maintain?

Yes, it features a compact modular design with a single access cover and top entry to all internals, which facilitates easy maintenance and economical repair of components like check seats and captured springs.