2 U009M2-A-QT-FS
Item Number: 88004137
1
/
of
1
Regular price
$2,516.25
Special Order
When Will it Ship:
Contact for Lead Time
Estimated transit time: 2 to 5 Business Days
Brand - Watts
Couldn't load pickup availability
- Reduced Pressure Zone Backflow Preventer
- Weight: 36.6 lb
- Size: 2 inch
- Body Material: Bronze
- Maximum Working Pressure: 175 PSI
- Temperature Range: 33°F - 180°F
- Flood sensor with SentryPlus Alert technology
- Quarter-turn ball valve shutoffs
- Swivel union inlet and outlet connections
- Approved by ASSE 1013, AWWA C511, CSA B64.4, IAPMO
Description
Description
The Watts Series U009 Reduced Pressure Zone Backflow Preventer Assembly, 2 inch, protects potable water supplies from contamination caused by backsiphonage or backpressure. This bronze assembly features unique swivel union connections and 360-degree rotating elbow fittings for versatile installation. It includes two independent check valves, replaceable seats, and quarter-turn ball valve shutoffs. A built-in flood sensor with SentryPlus Alert technology detects excessive relief valve discharge, requiring an add-on connection kit for active alerts. It is designed for easy maintenance and is approved by ASSE 1013, AWWA C511, CSA B64.4, and IAPMO. Item number 88004137.
Help Me Connect
Help Me Connect
Connections
- The assembly features unique swivel union inlet and outlet connections, allowing for flexible installation.
- Elbow fittings provide 360-degree rotation, making it adaptable to various piping configurations.
- Quarter-turn, full-port ball valve shutoffs are integrated for easy system isolation.
Flood Sensor Connectivity
To activate the integrated flood sensor, an add-on connection kit (sold separately) is required. This kit enables the sensor to communicate alerts:
- BMS (Building Management System) Integration: Connects to existing building management systems.
- Cellular Communication: Sends alerts via cellular network.
- Sensor Control Monitor: Integrates with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi for advanced monitoring.

Collapsible content
Additional Details
This Watts Series U009 Reduced Pressure Zone (RPZ) Backflow Preventer Assembly, 2 inch, is engineered to protect potable water supplies from pollution due to backsiphonage and backpressure, in accordance with national plumbing codes and water authority requirements.
Its compact, modular design facilitates straightforward maintenance, featuring a single access cover for in-line repairs.
Flood Sensor Technology
- Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
- An add-on connection kit (sold separately) is required to activate the flood sensor, enabling communication for alerts.
- Connection kit options include BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
- Watts is not responsible for the failure of alerts due to connectivity or power issues.
Design & Construction
- Bronze body construction ensures durability.
- Features two in-line, independent check valves, captured springs, and replaceable check seats for economical repair.
- An internal relief valve helps reduce installation clearances.
- Unique swivel union inlet and outlet connections and elbow fittings allow for 360-degree rotation, accommodating various installations.
- Equipped with quarter-turn, full-port, resilient seated ball valve shutoffs with convenient tee handles.
- Includes top-mounted ball valve test cocks with screwdriver slots for easy testing.
- Large body passages provide low pressure drop, contributing to a compact, space-saving design.
- No special tools are required for servicing.
Specifications
- Product Type: Reduced Pressure Zone Backflow Preventer
- Series: U009
- Size: 2 inch
- Model: U009M2-AQT-FS
- Body Material: Bronze
- Disc Material: Silicone rubber
- Check Seats Material: Replaceable polymer
- Relief Valve Seat Material: Removable stainless steel
- Cover Bolts Material: Stainless steel
- Maximum Working Pressure: 175 PSI (12 bar)
- Temperature Range: 33°F - 180°F (0.5°C – 82°C)
- Shutoff Valves: Quarter Turn Ball Valves
- Test Cocks: Ball Type, Screwdriver Slotted
- Connections: Swivel Union, Elbow Fittings
Certificates & Approvals
- ASSE Standard: 1013
- AWWA Standard: C511
- CSA: CSA B64.4
- IAPMO File No.: 1563
- UL Classified: Yes (for models with LF suffixes)
FAQs
What is the primary function of the Watts Series U009 backflow preventer?
The primary function is to protect potable water supplies from contamination by preventing the reverse flow of polluted water due to backsiphonage or backpressure, as required by plumbing codes.
How does the flood sensor work and what is required to activate it?
The assembly includes a flood sensor with SentryPlus Alert® technology that detects excessive water discharges from the relief valve. An add-on connection kit, sold separately, is required to activate the sensor and enable alert communication via BMS, cellular, or Wi-Fi platforms.
What material is the Watts U009 backflow preventer made from?
The body of the Watts Series U009 backflow preventer is constructed from durable bronze, ensuring long-lasting performance and resistance to corrosion.
What are the maximum operating pressure and temperature ratings for this device?
This backflow preventer has a maximum working pressure of 175 PSI (12 bar) and can operate within a temperature range of 33°F to 180°F (0.5°C to 82°C).
What certifications and approvals does this backflow preventer hold?
This Watts Series U009 assembly is approved by ASSE Standard 1013, AWWA C511, CSA B64.4, and IAPMO File No. 1563, confirming it meets rigorous industry standards.
Related Products
-
-
Item Number: 0881382
Watts 909-ELF (vertical) Air Gap Elbow Fitting
Regular price $261.00Limited Stock
1
/
of
2