4 4000SS-DOSY-GxG-FS

Item Number: F0694006
Skip to product information
1 of 1
Regular price $10,328.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 4 inch
  • Weight: 323.0 lb
  • Body Material: 300 Series Stainless Steel
  • Inlet Connection: Grooved
  • Outlet Connection: Grooved
  • Shutoff Valves: Domestic OSY Gate Valves
  • Maximum Working Pressure: 175 PSI
  • Features SentryPlus Alert® flood sensor
  • Half the weight of competitive designs

Description

This 4 inch AMES Series 4000SS Reduced Pressure Zone Backflow Preventer Assembly is designed to protect potable water supplies from contamination caused by backsiphonage and backpressure in health hazard cross-connections. Featuring a lightweight, corrosion-resistant 300 Series stainless steel body and grooved inlet/outlet domestic OSY shutoff valves, it offers easy installation and maintenance. The integrated SentryPlus Alert® flood sensor detects excessive relief valve discharge, providing notification capabilities when paired with an add-on connection kit. With a maximum working pressure of 175 PSI and compact dimensions, this assembly is ideal for demanding industrial and commercial applications.

Help Me Connect

This 4 inch backflow preventer assembly features grooved inlet and grooved outlet connections, designed for secure and efficient installation into compatible piping systems. The domestic Outside Stem and Yoke (OSY) resilient seated gate valves facilitate straightforward integration. For enhanced flood monitoring, an add-on connection kit (sold separately) is required to activate the integrated flood sensor, enabling communication with Building Management Systems (BMS), cellular networks, or the Nexa® platform via Wi-Fi when utilizing the Sensor Control Monitor.

View full details

Collapsible content

Additional Details

This 4 inch stainless steel reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of contaminated water into the potable water supply due to backsiphonage or backpressure. It is ideal for protecting cross-connections in health hazard applications and from other contaminants at the service line entrance.

The Series 4000SS features a short lay length, lightweight stainless steel body, corrosive-resistant stainless steel relief valve, and patented cam-check assembly. This compact design with a single access cover ensures maximum flow at low pressure drop.

Flood Detection

  • Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events.
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Construction & Design

  • Stainless steel construction provides long-term corrosion resistance and maximum strength.
  • Stainless steel body is half the weight of competitive designs, reducing installation and shipping costs.
  • Short end-to-end dimensions make retrofitting easy.
  • Cam-check assembly provides maximum flow at low pressure drop.
  • No special tools required for servicing.
  • Compact construction allows for smaller enclosures.
  • Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs.
  • Domestic grooved inlet x grooved outlet outside stem and yoke (OSY) resilient seated gate valves.
  • All internal metal parts are 300 Series stainless steel.
  • Check assembly made of Noryl®.

WARNING: An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component that has no communication with any other device. Proper drainage is required in the event of a discharge.

Specifications

General

  • Size: 4 inch
  • Series: 4000SS
  • Body Material: 300 Series Stainless Steel
  • Internal Metal Parts: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Shutoff Valves: Domestic OSY (Outside Stem and Yoke) Resilient Seated Gate Valves
  • Inlet Connection: Grooved
  • Outlet Connection: Grooved
  • Minimum Operating Temperature: 33°F (0.5°C)
  • Maximum Operating Temperature: 110°F (43°C)
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Flange Dimension: AWWA Class D

Certificates & Approvals

  • ASSE 1013
  • CSA B64.5
  • UL Classified (OSY only)
  • FM Approved (OSY only)
  • AWWA C511-92

FAQs

What is the primary purpose of this backflow preventer?

This 4 inch Series 4000SS Reduced Pressure Zone Assembly is designed to protect the potable water supply from contamination due to reverse flow (backsiphonage or backpressure) of non-potable water, especially in health hazard cross-connection applications.

What type of connections does this assembly have?

This model features domestic Outside Stem and Yoke (OSY) resilient seated gate valves with both a grooved inlet and a grooved outlet connection for straightforward installation into piping systems.

What materials are used in the construction of the Series 4000SS?

The main valve body and all internal metal parts are constructed from 300 Series stainless steel for superior corrosion resistance and strength. The check assembly is made of Noryl®.

How does the flood sensor feature work?

The integrated SentryPlus Alert® flood sensor detects excessive water discharges from the relief valve. To activate alerts and communicate with external systems (like BMS or Wi-Fi platforms), an add-on connection kit (sold separately) is required.

What are the maximum operating pressure and temperature ratings for this backflow preventer?

This backflow preventer has a maximum working pressure of 175 PSI (12.1 bar). The operating temperature range is 33°F (0.5°C) to 110°F (43°C).