4 5000SS-OSY-GPM-FS

Item Number: F0690545
Skip to product information
1 of 1
Regular price $11,553.76
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Nominal Size: 4 inch
  • Weight: 325.0 lb
  • Body Material: 300 Series Stainless Steel
  • Maximum Operating Pressure: 175 PSI
  • Temperature Range: 33°F – 110°F
  • Features SentryPlus Alert® flood sensor
  • Includes Gallons Per Minute (GPM) meter
  • Inlet: Flanged Gate Valve, Outlet: Grooved Gate Valve
  • UL Classified and FM Approved

Description

The 4 inch Ames Series 5000SS Reduced Pressure Detector Assembly is a critical backflow prevention device for non-potable service applications like fire protection, irrigation, and industrial processing. Constructed with a lightweight 300 Series stainless steel body, it offers superior corrosion resistance and strength. This assembly includes OSY shutoff valves, a gallon per minute meter for leak detection, and an integrated SentryPlus Alert® flood sensor to detect excessive relief valve discharge. The sensor, when paired with an add-on connection kit, provides crucial flood alerts. It is UL Classified and FM Approved for reliable health hazard protection. Item number F0690545.

Help Me Connect

Backflow Prevention System

  • This 4 inch reduced pressure detector assembly is designed for installation at cross-connections to protect potable water supplies from hazardous materials.
  • It features OSY (Outside Stem and Yoke) resilient seated gate valves for reliable shut-off.

Physical Connections

  • The assembly connects with a flanged inlet gate valve and a grooved outlet gate valve.
  • The bypass line includes a meter and isolation valves for detailed flow monitoring.

Flood Sensor Connectivity

  • The integrated flood sensor with SentryPlus Alert® technology requires an add-on sensor connection kit to activate its flood alert capabilities.
  • Once activated, the sensor can communicate with Building Management Systems (BMS), cellular networks, or integrate with a BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi, using the Sensor Control Monitor.
View full details

Collapsible content

Additional Details

This 4 inch reduced pressure zone backflow preventer assembly prevents the reverse flow of fire protection substances and non-potable water from entering the potable water supply due to backsiphonage or backpressure. It is ideal for continuous pressure piping applications and cross-connections identified as health hazards.

Features

  • Stainless steel construction provides long-term corrosion resistance and maximum strength
  • Lightweight stainless steel body reduces installation and shipping costs
  • Short end-to-end dimensions allow for easy retrofit
  • Bottom-mounted relief valve reduces clearance requirements, especially when installed against an outside wall
  • Cam-check valves provide maximum flow at low pressure drop
  • No special tools required for servicing
  • Compact construction enables installation in smaller enclosures
  • Stainless steel relief valve with a balanced rolling diaphragm eliminates sliding seals and lowers maintenance costs
  • Detects underground leaks and unauthorized water use via the included gallon per minute meter
  • Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve
  • Flood alert feature activates with an add-on sensor connection kit, compatible with BMS and cellular network communication

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing, consult your local water authority, building, and plumbing codes.

Specifications

  • Nominal Size: 4 inch
  • Product Type: Reduced Pressure Detector Assembly
  • Main Valve Body Material: 300 Series Stainless Steel
  • All Internal Metal Parts Material: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Relief Valve Material: Stainless Steel
  • Meter Type: Gallons Per Minute (GPM) Meter
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F – 110°F (0.5°C – 43°C)

Connections

  • Inlet Connection: Flanged Gate Valve
  • Outlet Connection: Grooved Gate Valve
  • Shutoff Valves: OSY (Outside Stem and Yoke) Resilient Seated Gate Valves

Flood Detection System

  • Flood Sensor: Integrated with SentryPlus Alert® Technology
  • Flood Alert: Activated with add-on sensor connection kit for BMS or cellular network communication

Certificates & Approvals

  • AWWA: AWWA C511-92
  • ASSE: ASSE 1047
  • CSA: CSA B64.5
  • UL: UL Classified
  • FM: FM Approved

FAQs

What is the primary purpose of the Ames 5000SS Reduced Pressure Detector Assembly?

This assembly is designed to protect potable water supplies from contamination due to backsiphonage or backpressure of hazardous materials from non-pototable sources, such as fire protection systems, irrigation, or industrial processing.

Is this backflow preventer suitable for drinking water systems in the United States?

No, it is illegal to use this product in any plumbing system providing water for human consumption in the United States. It is intended for non-potable service applications.

What materials are used in the construction of this backflow preventer?

The main valve body and all internal metal parts are constructed from 300 Series stainless steel for superior corrosion resistance. The check assembly is made from Noryl®.

How does the integrated flood sensor function?

The assembly includes a SentryPlus Alert® flood sensor that detects excessive water discharges from the relief valve. To activate flood alerts and communication with BMS or cellular networks, an add-on sensor connection kit is required.

What are the connection types for the 4 inch 5000SS assembly?

This particular assembly features a flanged inlet gate connection and a grooved outlet gate connection. It is equipped with UL and FM Approved outside stem and yoke resilient seated gate valves.