4 LF880V-DNRS-FS

Item Number: F683142
Skip to product information
1 of 1
Regular price $13,209.90
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • Size: 4 inch
  • Weight: 445.0 lb
  • Body Material: Ductile Iron
  • Coating: Patented ArmorTek Epoxy Coating
  • Shutoff Valves: Domestic Non-Rising Stem (NRS)
  • Relief Valve Seat: Stainless Steel
  • Detects flood events with SentryPlus Alert technology
  • Protects against high hazard (toxic) fluids
  • Lead Free Construction

Description

This 4 inch lead free ductile iron reduced pressure zone (RPZ) backflow preventer assembly provides critical protection against high hazard (toxic) fluids in industrial water services. Featuring a robust ductile iron body with patented ArmorTek epoxy coating, it offers advanced corrosion resistance. Internal stainless steel components ensure maximum performance and durability. The integrated SentryPlus Alert flood sensor detects continuous relief valve discharge and can relay alerts via BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via Modbus or Wi-Fi through the Nexa platform. Item number F683142.

Help Me Connect

Primary Connection

  • This 4 inch reduced pressure zone (RPZ) backflow preventer assembly is designed for installation into water services for industrial installations and applications.
  • It includes domestic non-rising stem (NRS) shutoff valves for controlling water flow.

Sensor Integration

  • The integrated flood sensor with SentryPlus Alert® technology connects with an add-on sensor connection kit to extend flood monitoring capabilities.
  • For remote monitoring, the sensor can integrate with a Sensor Control Monitor, enabling connectivity to Building Automation Systems (BAS) via RS-485 Modbus or to the Nexa® platform through Wi-Fi.
  • Additional connection kit options support BMS and cellular communication for versatile alert delivery.
View full details

Collapsible content

Additional Details

This 4 inch lead free MasterSeries® configurable reduced pressure zone backflow preventer assembly is designed to protect against high hazard (toxic) fluids in water services to industrial installations and applications.

Flood Detection & Monitoring

  • Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve
  • Add-on sensor connection kit extends flood monitoring on compatible assemblies
  • Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa® platform by Wi-Fi connectivity
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor

Construction & Durability

  • Ductile iron body construction with patented 3-part advanced epoxy coating system (ArmorTek®) designed to limit both microbial induced (MIC) and exposed metal substrate corrosion
  • Combines the use of a stainless-steel relief valve seat and stainless-steel check components for maximum performance and durability
  • Stainless steel springs ensure reliable operation
  • Lead free construction for safe water applications

Design & Components

  • Configurable N-Pattern design for versatile installation
  • Includes domestic non-rising stem (NRS) shutoff valves
  • Consists of a lead free body, test cocks, spring loaded check valves, and a pressure differential relief valve
  • Field reversible relief valve for maintenance flexibility

Specifications

  • Product Type: Reduced Pressure Zone Backflow Preventer Assembly
  • Size: 4 inch
  • Body Material: Ductile Iron
  • Coating: Patented 3-part ArmorTek® Epoxy Coating System
  • Shutoff Valves: Domestic Non-Rising Stem (NRS)
  • Relief Valve Seat Material: Stainless Steel
  • Check Component Material: Stainless Steel
  • Spring Material: Stainless Steel
  • Pattern: Configurable N-Pattern
  • Lead Free: Yes
  • Relief Valve Discharge Rate (4 inch): 170 GPM (as sized by floor drain mfg.)

FAQs

What is the primary function of this backflow preventer?

This backflow preventer assembly is designed to protect industrial water services from contamination by high hazard (toxic) fluids, ensuring water safety in critical applications.

How does the SentryPlus Alert technology work?

SentryPlus Alert technology includes a flood sensor that detects continuous discharge from the relief valve. When paired with an add-on connection kit, it can relay alerts for potential flooding events.

What type of corrosion protection does this assembly have?

The ductile iron body is fused with a patented 3-part ArmorTek® epoxy coating system, which is designed to limit both microbial induced (MIC) and exposed metal substrate corrosion.

What kind of shutoff valves are included with this assembly?

This assembly is equipped with domestic non-rising stem (NRS) shutoff valves, which are commonly used in various plumbing and industrial applications.

Can the flood sensor integrate with building management systems?

Yes, the flood sensor can integrate with Building Automation Systems (BAS) via an optional Sensor Control Monitor, supporting RS-485 Modbus or Wi-Fi connectivity through the Nexa® platform, as well as BMS and cellular communication options.