4 LF886-WZ-DOSY-GPM-FS

Item Number: F8007411
Skip to product information
1 of 1
Regular price $16,124.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • 4 inch Lead Free Reduced Pressure Zone Detector Assembly
  • Weight: 342.0 lb
  • MasterSeries LF886W/WZ for N-pattern or Z-pattern orientation
  • ArmorTek® epoxy coating for superior corrosion resistance
  • Integrated flood sensor with SentryPlus Alert® technology
  • Stainless steel relief valve seat and check components
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F – 140°F continuous
  • Designed for drop-in replacement of competitor's Z-pattern valves

Description

The FEBCO 4 inch MasterSeries LF886W/WZ Lead Free Reduced Pressure Zone Detector Assembly (Type II) protects potable water systems from high hazard/toxic contamination. This backflow preventer features a durable ductile iron body with ArmorTek® epoxy coating for corrosion resistance and stainless steel internal components for extended service life. It supports both N-pattern and Z-pattern orientations, offering a longer lay length for drop-in replacement of competitor valves. An integrated flood sensor with SentryPlus Alert® technology detects excessive relief valve discharge and can be connected to alert systems for immediate notification. The assembly includes OSY shutoff valves and a 5/8 inch x 3/4 inch GPM metered bypass. Item number F8007411.

Help Me Connect

Installation Orientation

  • This assembly is designed for installation on potable water supply lines.
  • The LF886W/WZ model supports both N-pattern (LF886W) for horizontal and Z-pattern (LF886WZ) for vertical-up orientations, offering flexibility for various piping configurations.
  • Its longer gate-to-gate length is specifically designed for drop-in replacement of existing competitor's Z-pattern valves, simplifying retrofits.

Flood Sensor Connectivity

  • The integrated flood sensor requires an add-on connection kit to activate its alert capabilities.
  • Connection kit options include those for Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor which enables integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.
View full details

Collapsible content

Additional Details

This 4 inch lead free MasterSeries® Reduced Pressure Zone Detector Backflow Preventer Assembly (Type II) provides superior protection against backpressure and backsiphonage in high hazard/toxic applications, commonly found in industrial installations and potable drinking water systems.

The assembly is designed for drop-in replacement of competitor's valves and features a ductile iron body with a specialized ArmorTek® epoxy coating for enhanced corrosion resistance. Internal components, including the relief valve seat and check components, are constructed from stainless steel for maximum performance and durability. An integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve, offering an advanced warning system.

Features

  • MasterSeries LF886W/WZ model designed for drop-in replacement of competitor’s valves in either N-pattern or Z-pattern orientation.
  • ArmorTek® patented three-part advanced epoxy coating system on iron components for superior protection against microbial-induced corrosion (MIC) and electrochemical corrosion.
  • Lead Free construction ensures the wetted surface contains less than 0.25% lead by weight, complying with low lead installation requirements.
  • Integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve.
  • Sensor relays a signal to trigger a multichannel alert (call, email, text) when activated by an add-on connection kit.
  • Stainless steel relief valve seat and stainless steel check components for maximum performance and durability.
  • Longer gate-to-gate length facilitates easy drop-in replacement.
  • Inline serviceable main valve assembly and bypass assembly require no special tools for maintenance.
  • Captured modular spring assembly, reversible and replaceable discs, and field replaceable seats.
  • Clapper check assembly with captured O-ring design.
  • Auxiliary bypass line with a 5/8 inch x 3/4 inch Gallons Per Minute (GPM) water meter (ANSI/AWWA C700 Compliant) for detecting potential underground water leaks or unauthorized water usage.
  • Equipped with domestic OS&Y resilient wedge gate shutoff valves (UL Classified and FM Approved).
  • Includes four properly located resilient seated ball valve test cocks.

An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device. Watts® is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.

Specifications

  • Nominal Size: 4 inch
  • Backflow Preventer Type: Reduced Pressure Zone Detector Assembly (Type II)
  • Valve Body Material: Ductile Iron Grade 65-45-12
  • Relief Valve Body Material: Ductile Iron Grade 65-45-12
  • Coating: ArmorTek® powder coating (internal and external surfaces)
  • Shutoff Valve Type: OSY resilient wedge gate valve
  • Check Seat Material: Stainless steel
  • Relief Valve Seat Material: Stainless steel
  • Disc Holder Material: Stainless steel
  • Elastomer Disc Material: Silicone
  • Spring Material: Stainless steel
  • Clamp Material: AWWA C506
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Minimum Working Pressure: 20 psi (1.4 bar)
  • Hydrostatic Test Pressure: 350 psi (24.1 bar)
  • Hydrostatic Safety Pressure: 700 psi (48.3 bar)
  • Temperature Range: 33°F – 140°F (0.5°C – 60°C) continuous
  • Lead Content: Wetted surface contains less than 0.25% lead by weight
  • Bypass Meter: 5/8 inch x 3/4 inch Gallons Per Minute (GPM) water meter
  • Flood Detection: Integrated sensor on relief valve (FS option)
  • Lay Length (N-Pattern, Approximate): 32 3/16 inch (818 mm)
  • Lay Length (Z-Pattern, Approximate): 32 13/16 inch (833 mm)
  • Weight (with OSY Valves, Approximate): 342 lb (155 kg)

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • ASSE 1047
  • UL Classified (US & Canada)
  • FM Approved
  • IAPMO/CUPC
  • AWWA Standard C511 Compliant
  • ASME B16.1 Class 125 (End Connections)
  • AWWA Class D Flange (End Connections)
  • CSA B64.4

FAQs

What is the primary use of the FEBCO LF886W/WZ Reduced Pressure Zone Detector Assembly?

This assembly is designed to protect potable drinking water systems from contamination due to backpressure and backsiphonage from high hazard/toxic applications, in accordance with local governing water utility codes.

What does "Lead Free" mean for this backflow preventer?

"Lead Free" means that the wetted surface of this product, which comes into contact with consumable water, contains less than 0.25% of lead by weight, complying with low lead installation requirements.

How does the integrated flood sensor work and what is required to use it?

The flood sensor detects excessive water discharges from the relief valve. To activate its alert capabilities for multichannel notifications (call, email, text, or BMS/cellular), an add-on connection kit is required. Without the kit, the sensor remains passive.

Can this backflow preventer replace existing competitor valves?

Yes, the MasterSeries LF886W/WZ is designed for drop-in replacement of competitor's valves, featuring a longer gate-to-gate length and supporting both N-pattern and Z-pattern orientations, simplifying retrofits.

What are the main materials used in the construction of this backflow preventer?

The main valve body and relief valve body are made of ductile iron grade 65-45-12 with ArmorTek® epoxy coating. Internal components like check seats, relief valve seat, disc holder, and springs are stainless steel, and the elastomer discs are silicone.