6 4000SS-DOSY-GxG-FS

Item Number: F0694009
Skip to product information
1 of 1
Regular price $16,122.01
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • 6 Inch Reduced Pressure Zone Assembly
  • Weight: 511.0 lb
  • Body Material: 300 Series Stainless Steel
  • End Connections: Grooved Inlet x Grooved Outlet
  • Features SentryPlus Alert Flood Sensor
  • Maximum Working Pressure: 175 PSI
  • Domestic OSY Resilient Seated Gate Valves
  • Lightweight stainless steel body
  • Cam-check assembly for maximum flow

Description

A 6 inch stainless steel reduced pressure zone backflow preventer assembly, SKU F0694009, designed to protect potable water supplies from health hazard cross-connections and contaminants. It features a lightweight 300 Series stainless steel body, grooved inlet and outlet OSY resilient seated gate valves, and a cam-check assembly for maximum flow at low pressure drop. The integrated SentryPlus Alert flood sensor detects excessive relief valve discharge, with activation requiring an add-on connection kit for BMS, cellular, or Wi-Fi/Modbus integration. Approved by AWWA, ASSE, CSA B64.4, FM, and USC, it offers reliable protection at 175 PSI maximum working pressure.

Help Me Connect

Flood Sensor Activation

  • An add-on connection kit (sold separately) is required to activate the flood sensor's alert features.
  • Connection kit options allow for compatibility with BMS (Building Management Systems) and cellular networks.
  • The Sensor Control Monitor connection kit enables integration with BAS (Building Automation Systems) via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.

Connections

  • This assembly features grooved inlet and outlet connections for easy installation with compatible grooved piping systems.
View full details

Collapsible content

Additional Details

This 6 inch stainless steel reduced pressure zone backflow preventer assembly prevents the reverse flow of contaminated water into the potable water supply. It is ideal for protecting against health hazard cross-connections and other contaminants at the service line entrance.

Key Features

  • Features a flood sensor with SentryPlus Alert technology to detect continuous discharge from the relief valve.
  • An add-on connection kit (sold separately) is required to activate the flood sensor, enabling extended flood monitoring and integration with BMS, cellular networks, or BAS via RS-485 Modbus or Nexa platform by Wi-Fi.
  • Stainless steel construction ensures long-term corrosion resistance and maximum strength.
  • The lightweight stainless steel body is half the weight of competitive designs, reducing installation and shipping costs.
  • Short end-to-end dimensions allow for easier retrofitting and compact construction fits smaller enclosures.
  • Patented cam-check assembly provides maximum flow at low pressure drop.
  • Stainless steel relief valve with a balanced rolling diaphragm eliminates sliding seals and lowers maintenance costs.
  • Domestic outside stem and yoke resilient seated gate valves are groove by groove.
  • No special tools are required for servicing.

Installation, operation, and maintenance of this product must comply with all required instructions, codes, and regulations, including the need to provide proper drainage in the event of a discharge. The flood sensor does not replace this requirement, and Watts® is not responsible for alerts failing due to connectivity issues, power outages, or improper installation. Always read all installation instructions and product safety information thoroughly before beginning installation and inquire with governing authorities for local requirements.

Specifications

  • Size: 6 Inch
  • Product Type: Reduced Pressure Zone Assembly
  • Body Material: 300 Series Stainless Steel
  • Valve Type: Domestic OSY Resilient Seated Gate Valves, Spring Loaded Cam-Check Valves, Pressure Differential Relief Valve
  • End Connections: Grooved Inlet x Grooved Outlet
  • Flood Detection: SentryPlus Alert Flood Sensor
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C - 43°C)

Certificates & Approvals

  • Approved By: AWWA C511-92
  • Approved By: ASSE
  • Approved By: CSA B64.4
  • Approved By: FM
  • Approved By: USC
  • UL Listed
  • UL Classified

FAQs

What is the primary function of this backflow preventer?

This 6 inch reduced pressure zone assembly is designed to prevent contaminated water from flowing back into the potable (drinking) water supply, protecting against health hazards and other contaminants.

What type of connections does this assembly use?

This backflow preventer features grooved inlet and outlet connections, which are compatible with grooved piping systems for secure and efficient installation.

Does this backflow preventer include a flood sensor?

Yes, it includes a SentryPlus Alert flood sensor. This sensor detects excessive water discharges from the relief valve to help prevent flooding and costly damage.

How is the flood sensor activated for alerts?

An add-on connection kit (sold separately) is required to activate the flood sensor's alert features. These kits allow for integration with BMS, cellular networks, or BAS via RS-485 Modbus or Wi-Fi.

What is the body material of this backflow preventer?

The body is constructed from durable 300 Series stainless steel, which provides long-term corrosion resistance and maximum strength while being lighter than traditional materials.