8 4000SS-DOSY-FxG-FS

Item Number: F0694014
Skip to product information
1 of 1
Regular price $27,755.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 8 inch
  • Weight: 752.0 lb
  • Body Material: 300 Series Stainless Steel
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F - 110°F
  • Flood Sensor: SentryPlus Alert® Technology
  • Connections: Flanged Inlet x Grooved Outlet
  • Gate Valves: Domestic OSY Resilient Seated
  • Corrosion Resistance: Long-term stainless steel construction

Description

This 8 inch AMES Series 4000SS reduced pressure zone backflow preventer assembly is designed for protecting potable water supplies from health hazard cross-connections. Featuring a lightweight 300 Series stainless steel body, it offers superior corrosion resistance and ease of installation. It includes domestic OSY resilient seated gate valves with flanged inlet and grooved outlet connections. A built-in SentryPlus Alert flood sensor detects excessive water discharge, requiring an optional connection kit for activation. The assembly has a maximum working pressure of 175 PSI and operates between 33°F to 110°F. Item number F0694014.

Help Me Connect

Connections

  • The inlet side features a flanged connection.
  • The outlet side features a grooved connection.

Flood Sensor Connectivity

This backflow preventer includes a passive SentryPlus Alert® flood sensor. To activate flood monitoring and enable alerts, an add-on sensor connection kit (sold separately) is required. This kit can enable integration with Building Management Systems (BMS) via RS-485 Modbus, cellular communication, or the Nexa® platform through Wi-Fi.

View full details

Collapsible content

Additional Details

This 8 inch stainless steel reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of contaminated water into the potable water supply due to backsiphonage and/or backpressure. It is ideal for protecting health hazard cross-connections and preventing contaminants at the service line entrance.

Features

  • Stainless steel construction provides long-term corrosion resistance and maximum strength.
  • The stainless steel body is half the weight of competitive designs, reducing installation and shipping costs.
  • Short end-to-end dimensions make retrofitting easy.
  • Cam-check assembly provides maximum flow at low pressure drop.
  • No special tools required for servicing, simplifying maintenance.
  • Compact construction allows for smaller enclosures.
  • Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs.
  • Includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve.
  • The flood alert feature is activated with an add-on sensor connection kit (sold separately), compatible with BMS and cellular network communication.

It is required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements.

Specifications

  • Size: 8 inch
  • Body Material: 300 Series Stainless Steel
  • Internal Metal Parts: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Gate Valves: Domestic OSY Resilient Seated Gate Valves
  • Connections: Flanged Inlet x Grooved Outlet
  • Relief Valve: Stainless Steel with Balanced Rolling Diaphragm
  • Flood Sensor: SentryPlus Alert® Technology (requires add-on connection kit for activation)
  • Temperature Range: 33°F - 110°F (0.5°C – 43°C)
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Lead Free: Yes (wetted surface contains less than 0.25% lead by weight)

Certificates & Approvals

  • AWWA C511-92
  • ASSE 1013
  • CSA B64.5
  • UL Classified (OSY only)
  • FM Approved (OSY only)

FAQs

What is a reduced pressure zone (RPZ) backflow preventer?

A reduced pressure zone backflow preventer is a mechanical device designed to protect potable water supplies from contamination due to backsiphonage or backpressure by creating a pressure differential zone.

What is the primary use of this 8 inch backflow preventer?

This 8 inch Series 4000SS backflow preventer is designed to protect potable water systems from health hazard cross-connections where contaminated non-potable water could enter the drinking water supply.

What types of connections does this assembly have?

This 8 inch backflow preventer features a flanged connection on the inlet side and a grooved connection on the outlet side, utilizing domestic outside stem and yoke (OSY) resilient seated gate valves.

Does this backflow preventer include a flood sensor? How is it activated?

Yes, it includes a SentryPlus Alert® flood sensor on the relief valve to detect excessive water discharge. An add-on sensor connection kit (sold separately) is required to activate flood monitoring and enable alert notifications.

What are the operating pressure and temperature limits for this device?

The maximum working pressure for this assembly is 175 PSI (12.1 bar). It is designed to operate within a temperature range of 33°F to 110°F (0.5°C to 43°C).