8 994-OSY-GxG-FS

Item Number: F438612
Skip to product information
1 of 1
Regular price $33,150.75
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 8 inch
  • Weight: 688.0 lb
  • Body Material: 300 Series Stainless Steel
  • Inlet Connection: Grooved Gate
  • Outlet Connection: Grooved Gate
  • Shutoff Valve Type: OSY Resilient Seated Gate
  • Maximum Working Pressure: 175 psi
  • Flood Sensor: Included with SentryPlus Alert technology
  • Lead Free: Yes (less than 0.25% lead)

Description

The Watts 8 inch Series 994-OSY-GxG-FS is a lead free reduced pressure zone backflow preventer designed to protect potable water from hazardous cross-connections. This assembly features a durable 300 Series stainless steel body and outside stem and yoke (OSY) grooved shutoff valves. It includes a SentryPlus Alert flood sensor to detect excessive relief valve discharge, with alerts relayable via add-on connection kits to BMS, cellular networks, or Wi-Fi platforms. Certified to AWWA C511-92, CSA B64.5, ASSE 1013, UL, and FM standards, it ensures reliable protection for health hazard applications with easy maintenance.

Help Me Connect

Connections

  • The grooved inlet and outlet gate connections are designed to connect seamlessly with piping systems that also utilize grooved couplings, ensuring a secure and efficient installation.
  • This assembly features Outside Stem & Yoke (OSY) resilient seated gate valves. These valves are externally visible to confirm their open or closed position, which is crucial for compliance and operational safety.

Flood Sensor Connectivity

The integrated SentryPlus Alert flood sensor is designed to detect excessive water discharges from the relief valve. To enable its advanced alert capabilities, an add-on connection kit is required. Without this kit, the sensor is a passive component. These kits offer various communication options:

  • Connect to a Building Management System (BMS) for centralized monitoring.
  • Utilize cellular communication for remote alerts.
  • Integrate with a Sensor Control Monitor to connect to Building Automation Systems (BAS) via RS-485 Modbus or the Nexa platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 8 inch lead free reduced pressure zone assembly backflow preventer helps stop the reverse flow of liquids due to backpressure or backsiphonage, especially where potential health hazards exist. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs.

The assembly consists of a short lay length stainless steel body, test cocks, a corrosion resistant stainless steel bottom mounted relief valve, torsion spring check valves, and outside stem and yoke (OSY) grooved inlet and outlet gate valve connections.

This backflow assembly includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve. When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include Building Management Systems (BMS), cellular communication, and the Sensor Control Monitor which enables integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa platform through Wi-Fi.

Features

  • Stainless steel construction provides long term corrosion resistance and maximum strength.
  • Stainless steel body is half the weight of competitive designs, reducing installation and shipping costs.
  • Short end-to-end dimensions make retrofit easy.
  • Bottom mounted relief valve reduces clearance requirements when installed against an outside wall.
  • Torsion spring check valves provide maximum flow at low pressure drop and trouble-free operation.
  • No special tools required for servicing.
  • Compact construction allows for smaller enclosures.
  • Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs.
  • Flood sensor with SentryPlus Alert technology detects continuous discharge from the relief valve.
  • Flood alert feature activated with an add-on sensor connection kit, compatible with BMS and cellular network communication.

Notice: An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component that does not communicate with any other device.

Specifications

  • Product Type: Reduced Pressure Zone Assembly
  • Size: 8 inch
  • Model: Watts Series 994-OSY-GxG-FS
  • Application: Health Hazard Cross-Connections

Body & Internal Components

  • Main Valve Body Material: 300 Series Stainless Steel
  • All Internal Metal Parts: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Shutoff Valve Type: Outside Stem & Yoke (OSY) Resilient Seated Gate Valves
  • Relief Valve: Stainless Steel with Balanced Rolling Diaphragm
  • Lead Content: Wetted surface contacted by consumable water contains less than 0.25% lead by weight

Connections

  • Inlet Connection Type: Grooved Gate
  • Outlet Connection Type: Grooved Gate
  • Test Cocks: Four Ball-Type

Performance

  • Temperature Range: 33°F-110°F (0.5°C - 43°C) continuous
  • Maximum Working Pressure: 175 psi (12.1 bar)

Certificates & Approvals

  • AWWA Standard: AWWA C511-92
  • CSA Standard: CSA B64.5
  • UL Classification: UL Classified (OSY only, 2 1/2"-10")
  • ASSE Standard: ASSE 1013
  • FM Approval: FM Approved (OSY only, 2 1/2"-10")

FAQs

What is the primary purpose of this 8-inch backflow preventer?

This 8 inch Reduced Pressure Zone (RPZ) backflow preventer is designed to protect potable water supplies by preventing the reverse flow of hazardous materials due to backpressure or backsiphonage, particularly in health hazard cross-connection applications.

Is this Watts Series 994 assembly considered lead-free?

Yes, the wetted surface of this product that comes into contact with consumable water contains less than one quarter of one percent (0.25%) of lead by weight, meeting lead-free requirements.

How does the SentryPlus Alert flood sensor function?

The integrated flood sensor detects excessive water discharges from the relief valve. To activate its alert capabilities and communicate with other devices (like BMS or cellular networks), an add-on connection kit is required. Without this kit, the sensor operates passively.

What type of connections does this backflow preventer use?

This assembly features 8 inch grooved inlet and outlet gate connections. It is equipped with Outside Stem & Yoke (OSY) resilient seated gate valves, which are commonly used in fire protection and waterworks applications for positive shutoff.

What are the main materials used in the construction of this backflow preventer?

The main valve body and all internal metal parts are constructed from 300 Series Stainless Steel, providing excellent corrosion resistance and strength. The check assembly components are made from Noryl®.