8 LF866-OSY-GPM-FS

Item Number: F683182
Skip to product information
1 of 1
Regular price $42,860.01
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • Size: 8 inch
  • Weight: 835.0 lb
  • Lead Free: Yes, less than 0.25% lead by weight
  • Body Material: Ductile Iron Grade 65-45-12
  • Coating: ArmorTek® corrosion protection
  • Max. Working Pressure: 175 psi
  • Temperature Range: 33°F - 140°F continuous
  • Shutoff Valves: UL Classified and FM Approved OS&Y Gate Valves
  • Detector: Flood sensor with SentryPlus Alert® technology

Description

The 8 inch FEBCO MasterSeries® LF866 Reduced Pressure Zone Detector Assembly provides reliable protection against backpressure and backsiphonage in high hazard/toxic applications for potable water systems. Featuring a durable ductile iron body with patented ArmorTek® anti-corrosion coating, this lead-free backflow preventer includes OS&Y shutoff valves, a gallons per minute bypass meter, and a flood sensor with SentryPlus Alert® technology for discharge detection. It ensures superior performance and extended valve life for industrial and commercial installations. Item number F683182.

Help Me Connect

This FEBCO MasterSeries® LF866 Reduced Pressure Zone Detector Assembly is designed for installation on potable water supplies at points of cross-connection. It provides critical protection against backpressure and backsiphonage conditions in high hazard/toxic applications, such as industrial facilities.

Connections

  • End connections are compliant to ASME B16.1 Class 125 and AWWA Class D Flange standards.
  • The integral flood sensor with SentryPlus Alert® technology requires an add-on connection kit (e.g., for BMS or cellular network communication) to activate its alert relay function for excessive water discharges from the relief valve.
  • The auxiliary bypass line includes a 5/8 inch x 3/4 inch water meter that complies with ANSI/AWWA Standard C700.
View full details

Collapsible content

Additional Details

This 8 inch Lead Free MasterSeries® Reduced Pressure Zone Detector Assembly (Type II) is designed to protect potable drinking water systems from backpressure and backsiphonage conditions in high hazard/toxic applications, adhering to Local Governing Water Utility Codes.

The backflow preventer's iron components are coated with ArmorTek®, a patented three-part advanced epoxy system engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate. This assembly also includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.

Main Valve Features

  • Stainless steel relief valve seat and stainless steel check components for maximum performance and durability
  • Inline serviceable assembly; no special tools required
  • Captured modular spring assembly
  • Reversible and replaceable discs
  • Field replaceable seats
  • Ductile iron valve body design
  • ArmorTek coating technology to resist corrosion of internals
  • Modular and repairable pressure differential relief valve
  • Clapper check assembly
  • Captured O-ring design
  • Sensor on relief valve for flood detection, activated by add-on connection kit for BMS or cellular network communication

Auxiliary Bypass Features

  • Compact design; remains in main valve assembly profile
  • Inline serviceable 3/4 inch check assembly; no special tools required
  • Field replaceable seat and disc
  • Detect potential underground water leaks
  • Detect unauthorized water usage

An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component that does not communicate with any other device. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

Specifications

  • Size: 8 inch
  • Product Type: Reduced Pressure Zone Detector Assembly (Type II)
  • Main Valve Body Material: Ductile iron Grade 65-45-12
  • Relief Valve Body Material: Ductile iron Grade 65-45-12
  • Coating: ArmorTek powder coating, applied to internal and external surfaces
  • Shutoff Valves: OSY resilient wedge gate valve AWWA C515 (UL Classified and FM Approved)
  • Check Seats Material: Stainless steel
  • Relief Valve Seat Material: Stainless steel
  • Disc Holder Material: Stainless steel
  • Elastomer Disc Material: Silicone
  • Spring Material: Stainless steel
  • Bypass Meter: 5/8 inch x 3/4 inch GPM water meter (ANSI/AWWA C700 Compliant)
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Minimum Working Pressure: 20 psi (1.4 bar)
  • Hydrostatic Test Pressure: 350 psi (24.1 bar)
  • Hydrostatic Safety Pressure: 700 psi (48.3 bar)
  • Temperature Range: 33°F - 140°F (0.5°C ~ 60°C) continuous
  • Lead Content: Less than 0.25% of lead by weight (wetted surface)
  • Assembly Flow Orientation: Horizontal

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • ASSE 1047
  • UL Classified** (US & Canada)
  • FM Approved**
  • IAPMO/CUPC
  • AWWA Standard C511 Compliant
  • End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange
  • NSF Certified to NSF/ANSI/CAN 61 & 372

FAQs

What is the primary use of this backflow preventer?

This backflow preventer is designed to protect potable drinking water systems from backpressure and backsiphonage conditions in high hazard/toxic applications, complying with local water utility codes.

What is the purpose of the ArmorTek® coating?

The patented three-part advanced epoxy ArmorTek® coating is applied to the iron components to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate, enhancing the assembly's durability and lifespan.

Does this backflow preventer include a flood sensor?

Yes, it features a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve, signaling potential flooding events.

What is needed to activate the flood sensor's alert system?

An add-on connection kit is required to activate the flood sensor's communication capabilities. Without this kit, the flood sensor functions only as a passive component.

What are the main materials used in the construction of this assembly?

The main valve body and relief valve body are constructed from ductile iron (Grade 65-45-12). Internal components like check seats, relief valve seat, disc holder, and springs are stainless steel, while the elastomer discs are silicone.