8 LF886W-LG-GPM-FS
Item Number: F8007404
1
/
of
1
Regular price
$28,070.25
Special Order
When Will it Ship:
Contact for Lead Time
Estimated transit time: 2 to 5 Business Days
Brand - Febco
Couldn't load pickup availability
- Reduced Pressure Detector Assembly (RPDA)
- Weight: 658.0 lb
- Nominal Size: 8 inch
- N-Pattern for competitor drop-in replacement
- Includes flood sensor with SentryPlus Alert® technology
- Less shutoff valves configuration
- Gallons per minute (GPM) metered bypass
- Ductile iron body with ArmorTek® coating
- Maximum Working Pressure: 175 PSI
Description
Description
The FEBCO 8 inch LF886W-LG-GPM-FS MasterSeries® N-pattern Reduced Pressure Detector Backflow Preventer Assembly provides critical protection for potable water systems against high hazard backpressure and backsiphonage. This lead-free unit features a ductile iron body with ArmorTek® corrosion-resistant coating and stainless steel internal components for enhanced durability. Designed for competitor drop-in replacement, it includes a gallons per minute (GPM) metered bypass and an integrated SentryPlus Alert® flood sensor for detecting relief valve discharge. An add-on kit is needed to activate sensor alerts. Item number F8007404.
Help Me Connect
Help Me Connect
Installation Orientation
- This N-pattern assembly is designed for horizontal installation.
Lay Length & Compatibility
- Features a longer gate-to-gate lay length specifically for drop-in replacement of competitor's N-pattern valves, simplifying retrofits.
Flood Sensor Activation
- The integrated flood sensor requires an add-on connection kit for activation. Connection kits are available for BMS (Building Management System), cellular communication, or the Sensor Control Monitor for integration with BAS (Building Automation Systems) via RS-485 Modbus or Nexa® Wi-Fi platform. Without a kit, the sensor is passive.

Collapsible content
Additional Details
This 8 inch lead free MasterSeries® N-pattern reduced pressure detector backflow preventer assembly (RPDA) is designed to protect potable water systems from high hazard (toxic) fluids due to backpressure and backsiphonage, commonly found in industrial installations.
The LF886W-LG-GPM-FS features a longer lay-length for direct drop-in replacement of competitor's N-pattern valves and includes a gallons per minute (GPM) metered bypass.
Flood Detection Features
- Equipped with a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
- An add-on connection kit is required to activate the flood sensor and enable alerts.
- When activated, the sensor can relay alerts for potential flooding events via BMS, cellular communication, or integrate with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
- Without an add-on connection kit, the flood sensor acts as a passive component and does not communicate.
Construction & Design
- Ductile iron body coated with ArmorTek®, a patented three-part advanced epoxy system, to resist microbial-induced corrosion (MIC) and protect exposed metal.
- Stainless steel relief valve seat and stainless steel check components ensure maximum performance and durability.
- Features replaceable stainless steel check seats, a gallons per minute metered bypass, and ball valve test cocks.
- Designed with reversible and replaceable discs and a captured modular spring assembly for ease of maintenance.
- Lead Free construction complies with low lead installation requirements.
Specifications
- Product Type: Reduced Pressure Zone Detector Assembly (RPDA)
- Model: LF886W/WZ MasterSeries® (N-Pattern)
- Nominal Size: 8 inch
- Shutoff Valves: Less Shutoff Valves
- Bypass Meter: Gallons Per Minute (GPM)
- Flood Sensor: Included, with SentryPlus Alert® technology
- Main Valve Body Material: Ductile Iron Grade 65-45-12
- Relief Valve Body Material: Ductile Iron Grade 65-45-12
- Coating: ArmorTek® Powder Coating (internal and external surfaces)
- Check Seats Material: Stainless Steel
- Relief Valve Seat Material: Stainless Steel
- Disc Holder Material: Stainless Steel
- Elastomer Disc Material: Silicone
- Spring Material: Stainless Steel
- Clamp: AWWA C606
- Max Working Pressure: 175 PSI (12.1 bar)
- Min Working Pressure: 20 PSI (1.4 bar)
- Hydrostatic Test Pressure: 350 PSI (24.1 bar)
- Hydrostatic Safety Pressure: 700 PSI (48.3 bar)
- Temperature Range: 33°F – 140°F (0.5°C – 60°C) continuous
Approvals & Standards
- FCCCHR-USC Approved
- ASSE 1047 Approved
- UL Classified (US & Canada)
- FM Approved
- IAPMO/CUPC Approved
- AWWA Standard C511 Compliant
- End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange
FAQs
What type of backflow preventer is the FEBCO LF886W-LG-GPM-FS?
This is a MasterSeries® Reduced Pressure Zone Detector Assembly (RPDA) designed to protect potable water systems from backpressure and backsiphonage of high hazard fluids.
Does this assembly include shutoff valves?
No, this specific model (LG configuration) is supplied "less shutoff valves." Separate shutoff valves would need to be procured if required for the installation.
How does the flood sensor function?
The integrated SentryPlus Alert® flood sensor detects excessive water discharges from the relief valve. To activate its alert capabilities for BMS, cellular, or Wi-Fi communication, an add-on connection kit is required.
What are the key materials used in its construction?
The main valve and relief valve bodies are made from durable ductile iron with ArmorTek® powder coating. Internal components like check seats, relief valve seats, and springs are stainless steel, while the elastomer discs are silicone.
What is the maximum operating pressure and temperature for this backflow preventer?
This unit has a maximum working pressure of 175 PSI (12.1 bar) and can operate continuously within a temperature range of 33°F to 140°F (0.5°C to 60°C).
Related Products
1
/
of
2