Brand - Febco

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Nominal Size: 1/2 inch
  • Lead Free* Bronze Body Construction
  • SentryPlus Alert® Flood Sensor Included
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 32°F to 140°F
  • Easy Maintenance: Modular Check/Relief Valves
  • Certified to ASSE 1013 and CSA B64.4

Description

The FEBCO 1/2 inch LF860 Reduced Pressure Zone Backflow Preventer Assembly is designed for health-hazard applications, preventing the reverse flow of high hazard (toxic) fluids into potable water supplies. It features Lead Free* bronze construction and threaded quarter turn ball valves. An integrated SentryPlus Alert® flood sensor detects excessive relief valve discharges, and with an add-on connection kit, can send alerts to facility personnel or integrate with building management systems via Wi-Fi or Modbus. This assembly is ideal for industrial plants, hospitals, and critical water lines, offering maximum protection against backpressure and backsiphonage. Item number F683000.

Help Me Connect

This 1/2 inch FEBCO LF860 Reduced Pressure Zone Backflow Preventer Assembly features threaded quarter turn ball valves for connection into your water system. It includes top-mounted test cocks for easy testing and maintenance. The integral flood sensor requires an add-on connection kit (sold separately) to enable communication and send alerts via BMS, cellular communication, or through the Sensor Control Monitor for BAS/Nexa platform integration. This assembly is designed to protect potable drinking water systems from high hazard cross-contamination.

View full details

Collapsible content

Additional Details

This 1/2 inch lead free reduced pressure zone backflow preventer assembly prevents the reverse flow of high hazard (toxic) fluids from entering a potable water supply due to backsiphonage or backpressure. It is designed for critical applications in industrial plants, hospitals, and water systems requiring maximum protection.

Key Features

  • Equipped with a flood sensor featuring SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • Requires an add-on connection kit to activate the flood sensor and relay alerts for potential flooding events.
  • Supports integration with BMS (Building Management Systems) via cellular communication or a Sensor Control Monitor for BAS via RS-485 Modbus or the Nexa® platform via Wi-Fi.
  • Features Lead Free* construction, with wetted surfaces containing less than 0.25% lead by weight.
  • Designed for easy maintenance with modular relief valve and check valves.
  • Includes threaded quarter turn ball shutoff valves and top-mounted test cocks.

An add-on connection kit is required to activate the flood sensor's communication features; without it, the sensor is a passive component. Watts® is not responsible for the failure of alerts due to connectivity or power issues. Proper drainage must be provided for discharge events.

Specifications

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Nominal Size: 1/2 inch
  • Construction: Lead Free* Bronze Body
  • Shutoff Valves: Threaded Quarter Turn Ball Valves
  • Flood Sensor: SentryPlus Alert® Technology
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Hydrostatic Test Pressure: 350 PSI (24.1 bar)
  • Temperature Range: 32°F to 140°F (0°C to 60°C)

Materials

  • Valve Body: Lead Free* cast copper silicon alloy
  • Elastomers: Silicone
  • Springs: Stainless steel

Certificates & Approvals

  • ANSI/AWWA Conformance: C511
  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
  • ASSE Standard: 1013
  • CSA Standard: B64.4
  • NSF Certified: NSF/ANSI 61-G

FAQs

What is the primary purpose of the FEBCO 1/2 LF860 Reduced Pressure Zone Backflow Preventer?

Its primary purpose is to prevent the reverse flow of high hazard (toxic) fluids into a potable water supply, protecting against contamination from backsiphonage or backpressure conditions.

Does this backflow preventer come with a flood sensor?

Yes, it includes an integrated flood sensor with SentryPlus Alert® technology, designed to detect excessive water discharges from the relief valve.

Is an additional kit required to use the flood sensor's alert features?

Yes, an add-on connection kit is required to activate the flood sensor's communication capabilities for sending alerts or integrating with other systems like BMS, BAS, or the Nexa® platform.

What are the typical applications for this backflow preventer?

It is suited for applications in industrial plants, hospitals, morgues, mortuaries, chemical plants, irrigation systems, boiler feed lines, and general potable water lines requiring maximum protection.

What material is the body of the backflow preventer made from?