1 LF860-QT-RP-FS

Item Number: F683002
Skip to product information
1 of 1
Regular price $1,008.04
Limited Stock (6)
Estimated transit time: 2 to 5 Business Days Eligible for Express Shipping

Brand - Febco

  • Size: 1 inch
  • Lead Free Bronze Body Construction
  • Quarter Turn Shutoff Ball Valves
  • Flood Sensor with SentryPlus Alert Technology
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 32°F to 140°F
  • Inline Serviceable Design
  • Potable Water Protection

Description

The FEBCO 1 inch Lead Free Reduced Pressure Zone (RPZ) Backflow Preventer assembly (LF860-QT-RP-FS) is engineered to prevent the backflow of high hazard fluids into potable water systems. Featuring a Lead Free bronze body and quarter turn shutoff valves, this unit is ideal for industrial plants, hospitals, and irrigation systems. An integrated SentryPlus Alert flood sensor detects excessive water discharges from the relief valve, preventing potential damage. With a maximum operating pressure of 175 PSI, it ensures reliable cross-connection control. Item number F683002.

Help Me Connect

This FEBCO LF860 series backflow preventer includes an integrated flood sensor with SentryPlus Alert® technology, designed to detect excessive water discharges from the relief valve. The sensor is installed externally and does not affect the assembly's primary functions or certifications.

Activation & Integration

  • To activate the flood sensor's alert features, an add-on connection kit is required. Without this kit, the sensor acts as a passive component with no communication capabilities.
  • The flood sensor can be connected to various systems for alert notifications, including those compatible with BMS (Building Management Systems) and cellular communication.
  • When paired with the Sensor Control Monitor, the flood sensor can integrate with BAS (Building Automation Systems) via RS-485 Modbus or connect to the Nexa® platform through Wi-Fi connectivity, enabling remote alerts for potential flooding events.
View full details

Collapsible content

Additional Details

This 1 inch Lead Free Reduced Pressure Zone (RPZ) Backflow Preventer assembly is designed to prevent the reverse flow of high hazard (toxic) fluids into the potable water supply due to backsiphonage or backpressure. It is suitable for applications in industrial plants, hospitals, morgues, mortuaries, chemical plants, irrigation systems, boiler feed, and general water lines where maximum protection is required.

Features

  • Provides potable water protection against cross-connection contamination of high hazard (toxic) fluids in water services.
  • Features a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • Designed as an inline serviceable assembly, requiring no special tools for maintenance.
  • Flood alerts can be activated with an add-on sensor connection kit, compatible with BMS and cellular communication.
  • Sensor Control Monitor can integrate with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Components

  • Constructed with a Lead Free bronze body.
  • Includes threaded quarter turn ball valves for shutoff.
  • Features top mounted test cocks.
  • Equipped with spring loaded check valves.
  • Incorporates a pressure differential relief valve.

Notice: An add-on connection kit is required to activate the flood sensor's alert capabilities. Without this kit, the sensor acts as a passive component with no communication to other devices.

Specifications

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Model: LF860-QT-RP-FS
  • Nominal Pipe Size: 1 inch
  • Body Material: Lead Free Cast Copper Silicon Alloy
  • Shutoff Valves: Quarter Turn Ball Valves
  • Flood Sensor: SentryPlus Alert® Technology
  • Wetted Surface Lead Content: Less than 0.25% by weight

Performance

  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Hydrostatic Test Pressure: 350 PSI (24.1 bar)
  • Temperature Range: 32°F to 140°F (0°C to 60°C)

Materials

  • Elastomers: Silicone
  • Springs: Stainless steel
  • Relief Valve Seat: Noryl®

Certificates & Approvals

  • ANSI/AWWA C511
  • ASSE 1013
  • CSA B64.4
  • NSF 61-G
  • NSF 372

FAQs

What is the primary function of the FEBCO 1 inch LF860-QT-RP-FS backflow preventer?

This backflow preventer is designed to protect potable drinking water systems from cross-contamination by preventing the reverse flow of high hazard (toxic) fluids due to backsiphonage or backpressure.

What does 'Lead Free' mean for this product?

The 'Lead Free' designation indicates that the wetted surfaces of the product, which come into contact with consumable water, contain less than 0.25% lead by weight, complying with modern installation requirements.

How does the SentryPlus Alert flood sensor work and what does it do?

The flood sensor detects excessive water discharges from the relief valve. When activated with an add-on connection kit, it relays a signal to facility personnel, triggering alerts for potential flooding events and allowing for corrective action.

Is an additional connection kit required for the flood sensor to provide alerts?

Yes, an add-on connection kit is required to activate the flood sensor's alert capabilities. Without this kit, the sensor is a passive component and does not communicate with other devices.

What are the typical applications for this backflow preventer?

This assembly is commonly used in industrial plants, hospitals, morgues, chemical plants, irrigation systems, boiler feed lines, and other water services requiring maximum protection against high hazard cross-connection contamination.